Service Manual
Step
9. Remove stepping motor
Remove the screw fixing step motor and
then remove the step motor.
10. Remove motor and cross flow blade
a
Remove the screws fixing motor clamp
and then remove the motor clamp.
b
Remove the screws at the connection
place of cross flow blade and motor; lift
the motor and cross flow blade upwards
to remove them.
c
Remove the bearing holder sub-assy.
Installation and Maintenance
Procedure
Screws
Holder sub-assy
Step motor
Screws
Motor clamp
Cross flow
Motor
Bottom case
91