Lennox LNINVE052 Service Manual page 63

Refrigerant r410a
Table of Contents

Advertisement

Drop
malfunction
32
U3
of DC busbar
voltage
Low voltage
33
protection of
PL
DC bus bar
Limit/
decrease
frequency due
34
EU
to module
temperature
protection
4-way valve is
35
U7
abnormal
60
Flash
20 times
every 3s
Flash
21 times
every 3s
During cooling
and drying
operation,
compressor and
Power voltage
outdoor fan stop
is unstable, big
while indoor
fluctuation.
fan operates.
During heating
operation, all
loads stop.
During cooling
The voltage at
and drying
positions L and N
operation,
on wiring board
compressor and
(XT) is lower than
outdoor fan stop
150 VAC
while indoor
Hardware
fan operates.
malfunction of
During heating
outdoor unit's
operation, all
main board;
loads stop.
Radiating grease
on IPM module
All loads
of outdoor unit's
operates
main board is not
normally, while
enough; screws
operation
haven't been
frequency of
fixed tightly;
compressor
decreases.
Hardware
malfunction of
outdoor unit's
main board;
Power voltage
is lower than
AC175V
Wiring terminal
This malfunction
4V is loose or
occurs under
broken
heating
operation: all
loads stop.
Hardware
malfunction of
outdoor unit's
main board;
Service Manual
1. Check
whether power
supply network is
abnormal;
1. Check
whether power
supply network is
abnormal;
2. Replace
outdoor unit's
main board AP1;
1. After the
system is de-
energized for
20min and
discharge,
check whether
radiating grease
on IPM Module
of outdoor
control board
AP1 is enough
and whether the
radiating is fixed
tightly;
2. Replace
outdoor unit's
main board AP1;
2. After de-
energization,
insert OVC-
COMP tightly or
replace wiring
3. Replace
outdoor unit's
main board AP1;
Installation and Maintenance