Service Manual
11.2 Removal Procedure of Outdoor Unit
LNINVC052 LNINVC063
Step
1. Remove big handle,valve cover and top cover
a
Remove the screw connecting the big handle
and right side plate, and then remove the big
handle.
Remove the screw connecting the valve cover
and right side plate, and then remove the valve
cover.
b
Remove the screws connecting the top cover
with outer case, right side plate and left side
plate; lift the top cover upwards to remove it.
Installation and Maintenance
Warning: Be sure to wait for a minimum of 20 minutes after
turning off all power supplies and discharge the refrigerant
completely before removal.
Procedure
right side
plate
big handle
right side plate
top panel
cabinet
screw
screw