Replacing The System's Fans - Kontron Embedded Computers KISS 4U User Manual

Table of Contents

Advertisement

Maintenance and Prevention

Replacing the System's Fans

The KISS 4U-Platform should only be operated with a functioning
fan slide-in module (refer to the "Replacing the System's Fans"
section).
Defective components should only be replaced by Kontron original
spare parts.
❏ part number of the fan slide-in module: 0-0084-3604
The fan slide-in module may be changed while the KISS 4U-
Platform is powered-up. This maintenance should only be carried
out by service personnel or users suitably instructed and sufficiently
informed about the associated dangers.
Keep your hands and fingers away from rotating parts of the fans.
Before taking out the fan slide-in module, wait until the fans have
totally stopped.
To replace fan slide-in module, proceed as follows:
1. Open the unit as described in the "Accessing Internal Components" section,
step 2-3. Pull out the device cover only so far as necessary to have access to
the fan slide-in module.
2. Loosen the captive knurled screw (Fig. 24, pos. 4). Use the handle (Fig. 24,
24a, pos. 2) of the fan slide-in module and pull it out from the fan case (Fig.
24c, pos. 9).
Fig. 24: KISS 4U-Platform with fan slide-in module (Detail)
36
1
2
3
4
KISS - User's Manual (V1.10)