Position Indicator (A-Cs-Sysecpi); Technical Data; Figure 9-4: Dimensions Of Position Indicator And Junction Box - NBN Fluke CS400 Hardware Manual

Kiln shell temperature monitoring
Table of Contents

Advertisement

9.5 Position Indicator (A-CS-SYSECPI)

Figure 9-4: Dimensions of Position Indicator and Junction Box

9.5.1 Technical Data

Switching distance
Temperature range
Length of cable
Protection rate:
Output
Junction Box
Position indicator
Electronic component
with cable to the sensor head
max. 20 mm (0.79 in.)
positioned to steel St37, sized 50 mm in square (2.16 in. in square)
position indicator: -25 to 230°C (-13 to 446°F)
junction box:
-25 to 70°C (-13 to 158°F)
5 m (15 ft)
IP67
No. 2: active 24 V / 300 mA max.
short circuit protected
Pin 2 (brown cable): + 24 VDC (7 to 40 VDC), ripple max. 15 %
Pin 3 (black cable): output active
Pin 1 (blue cable):
0 V
Junction box
Mounting hole
d=5.2 mm (0.205)
Appendix – Technical Data
Position Indicator (A-CS-SYSECPI)
Mounting hole
d=5.2 mm (0.205)
PG9 cable gland for
field cable
9
65

Advertisement

Table of Contents
loading

Related Products for NBN Fluke CS400

Table of Contents