Technical Data; Measurement Specification; Optical Specifications; Electrical Specifications - NBN Fluke CS400 Hardware Manual

Kiln shell temperature monitoring
Table of Contents

Advertisement

CS400 System
Hardware Manual, Rev. 1.0, Sep 2021

2 Technical Data

2.1 Measurement Specification

Temperature range
Spectral response
Detector
Accuracy
Repeatability
Temperature resolution
Sampling rate

2.2 Optical Specifications

Scan angle (FOV)
Measurement resolution 170:1 (IFOV = 5.9 mrad)
Spot detection
Focus

2.3 Electrical Specifications

System power
Ethernet
Alarm output

2.4 Environmental Specifications

Ingress protection
Ambient temperature
Warm-up time
Lifetime
1
measured at slit response at 20 Hz scan rate, pixel at focus distance
2
measured at slit response at 20 Hz scan rate, pixel at focus distance
14
100 to 650°C (212 to 1202°F)
3.5 to 4 µm
HgCdTe
± 0.5% of reading or ± 3°C (± 6°F) whichever is greater,
at 0 to 50°C (32 to 122°F) ambient temperature for the scanner
± 1°C (± 2°F)
at 0 to 50°C (32 to 122°F) ambient temperature for the scanner
0.1 K (digital interface)
1024 pixel per scan line
90°
1
, 90% energy
2
510:1 (IFOV = 2.0 mrad)
, 50% energy
infinity
100 to 240 VAC (for the system connection box)
TCP/IPv4 protocol 10/100 MBit/s, electrically isolated, auto-negotiation
192.168.42.30 – default for the first scanner
IP address:
192.168.42.31 – default for the second scanner
potential-free relay contacts: max. 30 V / 1 A, normally open / normally closed
IP65 (IEC529) – for the linescanner
-40 to 50°C (-40 to 122°F), – for scanner with housing, without cooling, no direct
sunlight
20 min.
40,000 h MTBF (mean-time between failure), for the scanning system
+1 for each further scanner