Connection Box; Technical Data; Figure 9-2: Connection Box - NBN Fluke CS400 Hardware Manual

Kiln shell temperature monitoring
Table of Contents

Advertisement

9.2 Connection Box

The connection box is used for the following items:
System connection box in the field
Fiber Optic Converter Box in the control room
TSM – Tire Slip Monitoring (A-CS-TSM-KIT-485)

9.2.1 Technical Data

Box
Temperature range
Dimensions (W x H x D)
Net weight
Protection rate:
Power supply
Wiring
Power input
Fuse

Figure 9-2: Connection Box

sheet steel, powder-coated
0 to 50°C (32 to 122°F)
-30°C (-22°F) with internal heater A-CS-CAB-HEAT for the system
connection box
380 x 380 x 210 mm (15 x 15 x 8.3 in)
approx. 12 kg (26 lb)
IP66 (NEMA 4)
100 to 240 VAC, 50/60 Hz
cable diameter max. 2.5 mm² (AWG 14)
max. 110 W (for the system connection box)
max. 30 W (for the fiber optic converter box)
6 A (fuse only with system connection box)
Appendix – Technical Data