Break away fitting for submersible sewage pump (12 pages)
Summary of Contents for Crane WEINMAN 6012CV
Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notifi cation.
(fl ammable, caustic, etc.) unless the pump is specifi cally designed and designated to handle them. Other brand and product names are trademarks or registered trademarks of their respective holders. Weinman® is a registered trademark of Crane Pumps & Systems, Inc. 8/2004, 5/06, 9/06 Alteration Rights Reserved...
During removal, great care must be taken Systems, Inc., Service Department in Piqua, Ohio, telephone to avoid dropping any part of the seal. Take (937) 778-8947 or Crane Pumps & Systems Canada, Inc., particular care not to scratch the lapped faces Bramton, Ontario, (905) 457-6223.
Figure 2 - MECHANICAL SEAL REASSEMBLY Press wearing rings (25) and (27) into the casing Reassembly will generally be in reverse order of (1) and casing cover (11). Rings should not be disassembly. If disassembly was not complete, use only hammered into place.
Page 5
PUMP TROUBLES AND THEIR CAUSES FAILURE TO PUMP PUMP LOSES PRIMING 1. Pump not properly primed 1. Air leaks in suction line 2. Wrong direction of rotation 2. Excessive amount of air in water 3. speed too low 3. Excessive suction lift and pump operating 4.
Page 6
Limited 24 Month Warranty Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights which vary from state to state.
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.