Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notification. A Crane Co. Company...
Other brand and product names are trademarks or registered trademarks of their respective holders. Weinman® is a registered trademark of Crane Pumps & Systems, Inc. 1997, 1998, 2000, 2003, 5/06, 9/06 Alteration Rights Reserved...
For the location of the nearest Weinman Service Center, check your Weinman representative or Crane Pumps & Systems Service Department in Piqua, Ohio, telephone (937) 778-8947 or Crane Pumps & Systems Canada, Inc., Brampton, Ontario, (905) 457-6223. Figure 2. Adjusting Wedges for Mounting Figure 1.
Page 4
Adjust the metal supports or wedges until the shafts of the pump and driver are level. Check the coupling faces, as well as the suction and discharge flanges of the pump for horizontal or vertical position by means of a level. ANGULAR Correct the positions, if necessary, by adjusting the MISALIGNMENT...
Page 5
4. GROUTING 3. If conditions require the use of a foot valve and Grouting compensates for unevenness in the foundation strainer, the flow area of the foot valve should be and prevents vibration and shifting after mounting is from 1-1/2 to 2 times the area of the suction pipe; complete.
pump. When closing the valve, a final “bumping” action with a • Drain/Purge plugs furnished to routinely remove wrench gives the final positive seal closure. foreign particles and protect pump and other system components. TDV MAINTENANCE: • Optional pressure tap allows monitoring of strainer The TDV valve requires no day-to-day maintenance or condition.
REPLACEMENT PROCEDURE: 1. Position clapper firmly against the seat face. 2. Pre-load spring and bind using filament tape (see Figure 4a) 3. Take the clapper pin with the extension screw and insert the pin into the spring and support hangers (see Figure 4b) 4.
Some pumps are equipped with three phase motors. Three or plug at the top of the pump casing, and inserting a phase motors require magnetic starters, and can run in pipe nipple in the orifice with an appropriate increaser to either direction, depending on how they are connected to accommodate a hose connection.
DO NOT START THE PUMP UNTIL IT IS FILLED WITH WATER. 14. STUFFING BOX - MECHANICAL SEAL With the exercise of a few precautions a mechanical seal will furnish very satisfactory operation in pumps. Precautions which should be observed are: 1.
Page 11
SERVICE GUIDE TROUBLE AND CAUSE REMEDY 1. Failure to pump a. Pump not properly primed a. Be sure that pump case and suction line are full of water. See priming instructions. b. Suction lift too great b. Locate the pump closer to the water source. Make sure that the suction piping diameter is large enough.
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
Need help?
Do you have a question about the WEINMAN 320 and is the answer not in the manual?
Questions and answers