Gasboy Islander PLUS Installation Manual page 74

Table of Contents

Advertisement

Table 3-2. Islander PLUS Terminal Block -4 Mechanical Pump – Connections Definition
Terminal No.
3
RX-RS232
4
RS-485 GND
5
RS-485_+
6
RS-485_-
7
PULSER_1
8
PULSER_2
9
PULSER_3
10
PULSER_4
11
GND_1_P
12
GND_2_P
13
GND_3_P
14
GND_4_P
15
+12V_1_P
16
+12V_2_P
17
+12V_3_P
18
+12V_4_P
19
IN USE 1 A
20
IN USE 2 A
21
IN USE 3 A
22
IN USE 4 A
23
IN USE 1 B(-)
24
IN USE 2 B(-)
25
IN USE 3 B(-)
26
IN USE 4 B(-)
27
LINE 1
28
LINE 2
29
LINE 3
30
LINE 4
31
LOAD 1
32
LOAD 2
33
LOAD 3
34
LOAD 4
35
LINE IN (115/230v)
36
NEUTRAL IN (115/230v)
60
Signal Name
Functional Description
Receive Data interface
Data link to Density Probes Console Box /
Density Display
Chassis / Positive / Negative connections
Pulser Input – Nozzle 1
Pulser Input – Nozzle 2
Pulser Input – Nozzle 3
Pulser Input – Nozzle 4
Nozzle Grounding – Nozzle 1
Nozzle Grounding – Nozzle 2
Nozzle Grounding – Nozzle 3
Nozzle Grounding – Nozzle 4
+12 VDC Output to Pulser – Nozzle 1
+12 VDC Output to Pulser – Nozzle 2
+12 VDC Output to Pulser – Nozzle 3
+12 VDC Output to Pulser – Nozzle 4
Handle Up - In Use signal input - Nozzle 1
Handle Up - In Use signal input - Nozzle 2
Handle Up - In Use signal input - Nozzle 3
Handle Up - In Use signal input - Nozzle 4
Handle Up – AC In Use signal return - Nozzle 1
Handle Up – AC In Use signal return - Nozzle 2
Handle Up – AC In Use signal return - Nozzle 3
Handle Up – AC In Use signal return - Nozzle 4
Pump control 220/110 VAC Input - Nozzle 1
Pump control 220/110 VAC Input - Nozzle 2
Pump control 220/110 VAC Input - Nozzle 3
Pump control 220/110 VAC Input - Nozzle 4
Pump control output - Nozzle 1
Pump control output - Nozzle 2
Pump control output - Nozzle 3
Pump control output - Nozzle 4
Line Connection, Islander PLUS power input
Neutral Connection, Islander PLUS power input
Islander PLUS Manual

Advertisement

Table of Contents
loading

Related Products for Gasboy Islander PLUS

This manual is also suitable for:

Islander icr plus

Table of Contents