Table 3-2. Islander PLUS Terminal Block -4 Mechanical Pump – Connections Definition
Terminal No.
3
RX-RS232
4
RS-485 GND
5
RS-485_+
6
RS-485_-
7
PULSER_1
8
PULSER_2
9
PULSER_3
10
PULSER_4
11
GND_1_P
12
GND_2_P
13
GND_3_P
14
GND_4_P
15
+12V_1_P
16
+12V_2_P
17
+12V_3_P
18
+12V_4_P
19
IN USE 1 A
20
IN USE 2 A
21
IN USE 3 A
22
IN USE 4 A
23
IN USE 1 B(-)
24
IN USE 2 B(-)
25
IN USE 3 B(-)
26
IN USE 4 B(-)
27
LINE 1
28
LINE 2
29
LINE 3
30
LINE 4
31
LOAD 1
32
LOAD 2
33
LOAD 3
34
LOAD 4
35
LINE IN (115/230v)
36
NEUTRAL IN (115/230v)
60
Signal Name
Functional Description
Receive Data interface
Data link to Density Probes Console Box /
Density Display
Chassis / Positive / Negative connections
Pulser Input – Nozzle 1
Pulser Input – Nozzle 2
Pulser Input – Nozzle 3
Pulser Input – Nozzle 4
Nozzle Grounding – Nozzle 1
Nozzle Grounding – Nozzle 2
Nozzle Grounding – Nozzle 3
Nozzle Grounding – Nozzle 4
+12 VDC Output to Pulser – Nozzle 1
+12 VDC Output to Pulser – Nozzle 2
+12 VDC Output to Pulser – Nozzle 3
+12 VDC Output to Pulser – Nozzle 4
Handle Up - In Use signal input - Nozzle 1
Handle Up - In Use signal input - Nozzle 2
Handle Up - In Use signal input - Nozzle 3
Handle Up - In Use signal input - Nozzle 4
Handle Up – AC In Use signal return - Nozzle 1
Handle Up – AC In Use signal return - Nozzle 2
Handle Up – AC In Use signal return - Nozzle 3
Handle Up – AC In Use signal return - Nozzle 4
Pump control 220/110 VAC Input - Nozzle 1
Pump control 220/110 VAC Input - Nozzle 2
Pump control 220/110 VAC Input - Nozzle 3
Pump control 220/110 VAC Input - Nozzle 4
Pump control output - Nozzle 1
Pump control output - Nozzle 2
Pump control output - Nozzle 3
Pump control output - Nozzle 4
Line Connection, Islander PLUS power input
Neutral Connection, Islander PLUS power input
Islander PLUS Manual