Gasboy Islander PLUS Installation Manual page 117

Table of Contents

Advertisement

Fault
Probable Cause
OrPT display
OrPT is busy
does not respond
performing another
correctly to tags
task
Faulty OrPT
OrPT display
Bad key
does not respond
Faulty connection
correctly to keys
OrPT is busy
performing another
task
Faulty OrPT
Pressing the
Dirty keyboard
keypad buttons
Damaged keypad
does not generate
any sound and
does not affect
OrPT is busy
the display
performing another
task
Faulty OrPT
Islander PLUS Manual
Table 5-2. OrPT Troubleshooting (Cont'd)
Checks
OrPT does not accept RFID tag (Continued)
Verify that the display
presents the idle message
OrPT does not accept Gasboy key
Open the Islander PLUS
door and check the flat
wire which connects key
reader to the OrPT
terminal
Verify that the display
presents the idle message
OrPT does not respond to keypad entries
Visually check the keypad
surface for any damage
Verify that the display
presents the idle message
Corrective Action
1. Press Cancel
2. Present the tag while
the idle message is
displayed
Replace OrPT
Replace key and test again
Make good electrical
connection if faulty one
exists
1. Press Cancel
2. Present the tag while
the idle message is
displayed
Replace OrPT
Clean the keyboard
Replace keypad if any
damage is found
1. Press Cancel
2. Present the tag while
the idle message is
displayed
Replace OrPT
103

Advertisement

Table of Contents
loading

Related Products for Gasboy Islander PLUS

This manual is also suitable for:

Islander icr plus

Table of Contents