Fault
Probable Cause
OrPT display
Bad card/key
does not respond
Faulty connection
correctly to HID
cards/keys
OrPT is busy in
another task
Faulty OrPT
Communication
disconnected
5-LAN switch is
No power to 8-Port
dead
OrCU problem
Faulty connection
Power supply
failure
Faulty OrCU
104
Table 5-2. OrPT Troubleshooting (Cont'd)
Checks
OrPT does not accept HID card/key
Open the Islander PLUS
door and check the cable
which connects HID
reader to the OrPT
terminal
check that dsplay present
the idle message
OrPT displays "No communication" message
Open Islander PLUS door
and check LAN cable
from OrPT to 5-LAN
switch
Are 8-Port LEDs
lit/blinking?
Is 5-LAN switch LEDs
are lit/blinking?
Check power to OrCU
Is power supply on?
Corrective Action
Replace key and test again
Make good electrical
connection if faulty one
exists
1. Press Cancel
2. Present the card/key
while the idle message
is displayed
Replace OrPT
Make correct and good
connection if it was
incorrect
1. Check power connector
to 8-Port
2. Replace 8-Port
1. Check connection of
LAN switch on 8-Port.
It should be inserted in
a socket on the 8-port
main board
2. Replace 5-LAN switch
board
Verify that the white power
connector is plugged into
the OrCU POWER socket
1. Replace fuse
2. Replace power supply
Replace OrCU