Gasboy Islander PLUS Installation Manual page 111

Table of Contents

Advertisement

Fault
Probable Cause
Doesn't accept
OrPT setup is
Key/Card/Keypad
incorrect
input
No
OrCU setup is
communication
incorrect
No Magnetic
Dirty or faulty
Card response
Magnetic Card
reader
Faulty Magnetic
Cards
No Key response
Loose cable
Faulty key
receptacle
Customer display
Faulty Customer
is blank
display
Faulty OrPT
Pump does not
Device is not
supply fuel
allowed to refuel
Islander PLUS Manual
Table 5-1. Islander PLUS Troubleshooting (Cont'd)
Checks
System is down (Continued)
Login into OrPT and
check communication
parameters
Check OrCU setup:
• OrPT bus
• OrPT parameters
• OrCU Administrator
1. Visually check
2. Present several
1. Visually check Key
2. Insert several keys
Verify that customer
display board is properly
connected to OrPT
interface board
Mechanic pump does not refuel
1. Open the pump from
2. Verify that the
parameters
Magnetic Card reader
Magnetic Cards
receptacle
SiteOmat Status
screen
vehicle/device has no
limitation in FHO
setup
Corrective Action
1. Set communication
parameters
2. Submit and check again
1. Set communication
parameters
2. Save and reload
3. Check again
1. Clean Magnetic Card
reader
2. Replace Magnetic Card
reader
3. Replace OrPT
1. Replace Key receptacle
2. Replace OrPT
1. Replace customer
display
2. Replace OrPT
Enable the device to refuel
97

Advertisement

Table of Contents
loading

Related Products for Gasboy Islander PLUS

This manual is also suitable for:

Islander icr plus

Table of Contents