Electrical connection of the DB/DL system

The DB/DL system is to be connected as shown on figure 7. The DB/DL is to be connected to the sockets on the control box by
means of the motor cables, which have a 6-pin plug in each end.
Finally, the mains cable is to be mounted and power switched on. Please note that the control box must only be
connected to the voltage stated on the label.
CBD4/CBD5/CBD6 with earth
The CBD4/CBD5/CBD6 earth cable to be mounted on the desk construction (typically the top frame)in a way that ensures good
electrical contact. The function of the earth cable is to earth the desk and ground static electricity. The earth connection does
not protect other electrical products.
CBD4/CBD5 with mains cut-off (non ZERO models)
If the power cable is damaged it has to be replaced by an authorized LINAK service centre to avoid any danger.
Hook for cable relief
DP
DL/DB
Figure 7
Page 20 of 36
Mains cable