Mounting Guidelines For The Dl14 System; Mounting Top - Linak DESKLINE DL12 User Manual

Hide thumbs Also See for DESKLINE DL12:
Table of Contents

Advertisement

Mounting guidelines for the DL14 system

Mounting top

The top of the column is supplied with 4 M6 threaded holes meant for mounting onto the desk frame. We advise you to fasten
the desk frame by means of 4 pcs. M6 screws of a good quality (min. 8.8) and of a suitable length, which must not go further
than max. 14 mm into the column. The thrust moment must not exceed 10 Nm.
Screw length
Min. B + 9 mm
Max. B + 14 mm
Page 11 of 36