Mounting guidelines for the DL12 system
Mounting the top
The DL12 top plate is supplied with four M6 threaded
holes for mounting onto the top frame.
1. Mount column top on top frame using four M6 bolts
with the following specifications:
Quality: Min. grade 8.8
Length: Min. 12 mm (plus top frame thickness);
Max. 16 mm (plus top frame thickness)
2. Fasten bolts thoroughly (torque: max. 10 Nm).
Mounting the desk
The sound from the lifting column spreads as vibrations to the tabletop which amplifies the sound. This can, however, be
reduced.
1. Place vibration/shock-absorbing material between tabletop and top frame.
Mounting the feet
The DL12 bottom plate is supplied with four M6 threaded holes.
1. Mount column bottom on desk feet using four M6 bolts with
the following specifications:
Quality: Min. grade 8.8
Length: Min. 12 mm (plus desk feet thickness);
2. Fasten bolts thoroughly (torque: max. 10 Nm).
The holes in the foot must be sufficiently larger than ø6 to
enable levelling of the assembled desk.
M6
Floor level
Page 14 of 36
Max. 16 mm (plus desk feet thickness)
Table top
Absorbing
material