Mounting Guidelines For The Cbd4/Cbd5/Cbd6 - Linak DESKLINE DL12 User Manual

Hide thumbs Also See for DESKLINE DL12:
Table of Contents

Advertisement

Mounting guidelines CBD4/CBD5/CBD6
The control box is to be fastened with 4 screws (3 screws for the CBD5 and theCBD6) with a head diameter between ø 8 and
ø 10 mm. Out of regard for the surface tension ø 10 mm is preferable due to lower surface tension. See drawing appendix for
placing of mounting holes and the space the CBD takes up.
CBD4 - Control box
The CBD must not be packed in heat insulating material, but must be placed so that it can emit waste heat into the
surroundings. There are no ventilation holes to consider, the CBD emits heat through the surface.
The plug must be visible when the CBD is mounted so that the supply to the CBD can be disconnected at replacement, if any.
The mounting screws on the control box must be fastened with a max. torque of 1 Nm.
The mounting surface to which the control box is attached should have a surface evenness of better than
±0.5 mm.
CBD5/CBD6 - bottom with cable grooves
The bottom of the CBD5/CBD6 is equipped with two cable grooves improving the cable management when mounting. The
grooves can be used to bypass the CBD for both motor cables and the mains cable (EU version only) from one side to the other,
giving a cleaner design.
Remember to lead the cables through the grooves before mounting the control box.
For mounting and operation of the desk panel, please see the separate user manual for desk panels.
CBD5 - Control box
Page 19 of 36
CBD6 - Control box