6.6. Operating and Storage Temperatures
Table 41: Operating and Storage Temperatures
Parameter
Operating Temperature Range
Extended Operating Temperature
4
Range
Storage temperature range
3
Within operating temperature range, the module is 3GPP compliant.
4
Within the extended temperature range, the module remains the ability to establish and maintain functions such as voice,
SMS, data transmission, etc., without any unrecoverable malfunction. Radio spectrum and radio network are not influenced,
while one or more specifications, such as Pout, may exceed the specified tolerances of 3GPP. When the temperature
returns to the operating temperature range, the module meets 3GPP specifications again.
Min.
3
-35
-40
-40
LTE Standard Module Series
Typ.
Max.
+25
+75
-
+85
-
+95
Unit
°C
°C
°C