ID-NET INTERFACE

ID-NET Cables

The following instructions are referred to Figure 58, Figure 59 and Figure 60.
Baudrate Table
Baudrate
Cable Length
* Application dependent, contact your Datalogic representative for details.
NOTE
CBX100/500
Shield
ID+
ID-
REF
The general cable type specifications are: CAT5 twisted pair + additional CAT5
twisted pair, shielded cable AWG 24 (or AWG 22) stranded flexible.
We recommend using DeviceNet cables (drop or trunk type) to the following refer-
ence standards:
AN50325 – IEC 62026
UL STYLE 2502 80°C 30V
Cable Shield MUST be connected to earth ground ONLY at the Master.
NEVER use ID-NET cable shield as common reference.
The ID-NET max cable length depends on the baudrate used (see the Baudrate
Table below).
For Common Power Connections use only 2 wires (ID+ and ID-).
- DC Voltage Power cable (Vdc – GND) should be handled as a signal cable (i.e. do
not put it together with AC cable):
- Wire dimensioning must be checked in order to avoid voltage drops greater than
0.8 Volts.
- Cable should lie down as near as possible to the ID-NET cable (avoiding wide
loops between them).
Reader's chassis may be connected to earth.
Network inside the same building.
The default ID-NET baudrate is 500 kbps. Lower ID-NET baudrates allow
longer cable lengths.
Description
Network Cable Shield
ID-NET Network Data +
ID-NET Network Data -
Network Reference
125 kbps
250 kbps
1200 m
900 m
ID-NET INTERFACE
500 kbps
1 Mbps
700 m
*
PRODUCT REFERENCE GUIDE