Pandora Light v3 Manual page 29

Hide thumbs Also See for Light v3:
Table of Contents

Advertisement

• Confirmation of the PIN-code input
Confirm the entered PIN-code on this sublevel. Repeat the procedure described above and press the
VALET button. The system will compare two inputs after that.
- If you correctly enter the code twice, the indicator will produce the series of red and green flashes
and the Beeper will produce the series of sounds, the new code will be recorded, the system will return
to the programming level №0.
- In case of the incorrect code input the indicator will be lit red and the Beeper will sound a long beep,
the system will not change the code and will return to the programming level №0.
Level 12 Fuel level calibration
!
T
his prOcEdurE is usEd ONly iN casE Of aNalOg cONNEcTiON
. i
fuEl lEvEl
N sOmE casEs fuEl lEvEl calibraTiON shOuld bE pErfOrmEd by all spEcifiEd pOiNTs
To control fuel level, make connection and configure the settings:
Setting is performed via the Pandora Alarm Studio /Pandora Specialist Application». The «Use INP
to control fuel level» item should be enabled in the settings, the default setting of this input (input
settings) must be unselected. Make a connection in accordance with the «Fuel control input» scheme.
Fuel level calibration
• Select the desired sub-level corresponding to the current fuel level. The total number of sublevels are
12 (listed in the table). Enter the programming level 12. The LED indicator will be red and the system
will enter to the sublevel 12-0 (0%). Enter the number of the desired sublevel (10-100%) by pressing
the VALET button (press the button a number of times equals to a digit; pauses between presses
should not exceed 1 second).
• Start the engine for at least 1 minute, then press VALET button – the data will be sent to the base unit.
Press «Arming» button of the remote to save the setting. If you want to cancel the current setting,
press the «Disarming» button of the remote.
• To exit the programming mode, enter sublevel 12 or press VALET button more than 12 times.
• Repeat the procedure for the second and next calibration points.
Reset all calibration values
To reset all calibration values, proceed to the sublevel 11 (do not switch on the ignition). Reset
confirmation is performed by pressing «Arming» button of the remote, exit without confirmation and
exit the menu are performed by pressing the VALET button.
56
. a
2
T lEasT
valuEs arE rEquirEd fOr cOrrEcT display Of
(
fOr mOrE ExacT dEfiNiTiON
PA N D O R A L I G H T V 3
Sublevel
12-0
12-1
12-2
12-3
12-4
12-5
12-6
).
12-7
12-8
12-9
12-10
12-11
12-12
Level 13 - Emergency control of the code immobiliser
!
T
hE dETailEd iNfOrmaTiON is availablE iN
Level 17 – Programming bypass of the vehicle immobiliser system
Bypass learning procedure is performed on this level.
!
T
hE dETailEd iNfOrmaTiON caN bE fOuNd iN iNsTallaTiON schEmEs fOr a car ON ThE lOadEr
p
a
s
, p
aNdOra
larm
TudiO
U S E R A N D I N S TA L L AT I O N M A N UA L
Fuel level
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Reset all calibration values
Exit the programming mode
«E
mErgENcy cONTrOl Of ThE sysTEm
s
.
aNdOra
pEcialisT
»
sEcTiON
.
.
,
paNdOraiNfO
cOm
57