Removal Of Brake From Motor Assembly - Sunrise Medical Quickie Q50R Service Instructions Manual

Hide thumbs Also See for Quickie Q50R:
Table of Contents

Advertisement

Removal of brake from motor assembly

Preparation
Note! Switch off the wheelchair via remote control
Instructions
Note! Suitable work area required!
• Follow the illustrated instruction for the brake from the
motor assembly.
• In order to complete this, you must first disconnect the
power
• Please remove brake lever first in order to remove the
brake.
Fig. 6.2.23
1. Unscrew and remove 2 (A)screws from the main brake cover
using 3mm hex key(Please re-tighten by hand)
Fig. 6.2.24
2. Remove main brake cover (B) from motor
NOTE: Disconnect electrical connector after main brake cover has
been removed
Fig. 6.2.25
3. Unscrew and remove 4 (C) screws using 3mm hex key
21
Tools used
Q50R
REV.A

Hide quick links:

Advertisement

Table of Contents
loading