Contec F&eIT Series User Manual page 62

I/o controller module
Hide thumbs Also See for F&eIT Series:
Table of Contents

Advertisement

-
Trap transmission (command = 4)
This command is used by devices to send a signal to the controller when a trap event occurs (an
interval timer event or a pre-set event). If a response is required, the MSB in the command is set
to 0.
Trap frame (received data)
Identifier
= "SV"
Version
= 1
Command
= 84h
Note: 4h if a response is expected.
Sequence num ber = 1
Response ID
= 1234
Access size
= any
Status
= 0000h
Access ID
= Read ID
Data section
= any
Figure 8.8. Trap Transmission
-
Reset (command = 5)
This command resets a given device. Before resetting itself, the device will return a response
frame.
Command generation (transmitted data)
Identifier
= "SV"
Version
= 1
Command
= 5h
Sequence number = 1
Response ID
= 1234
Access ID
= R/W ID
Response frame (received data)
Identifier
= "SV"
Version
= 1
Command
= 85h
Sequence number = 1
Response ID
= 1234
Status
= 0000h
Figure 8.9. Reset Transmission
Response status
Following is a table of status information that is returned by response-type commands:
Table 8.9. Status Table
Code
Description
0000h
Normal termination
0001h
Access violation
0002h
Area error
0003h
Access size error
0004h
Parameter error
0005h
Length error
0006h
Insufficient resources
CPU-CA10(FIT)GY, CPU-CA20(FIT)GY
Event notification
RESET request
Response
An attempt was made to write to a Read-only area.
Access was made to an area not defined on the device.
An access request greater than 1436 bytes was made.
Invalid parameter contents, such as receipt of a non-supported command.
Invalid transmission length, such as an inconsistent data size with the
number of data items calculated from the UDP/IP.
Too many tasks are waiting for ACK data, causing a resource shortfall. The
resources can be released by a timeout.
8. System Reference
Device
Device
Reset processing
Remarks
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpu-ca10fitgyCpu-ca20fitgy

Table of Contents