8. System Reference
-
Message transmission (command = 3)
Writes the message to be transmitted into the data section. The result is received as a response
frame status. The maximum data size that can be transmitted per command is 1436 bytes.
(Example: data transmission)
Command generation (transmitted data)
Identifier
= "SV"
Version
= 1
Command
= 3h
Sequence number = 1
Response ID
= 1234
Access size
= 10
Access ID
= R/W ID
Data = 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
Response frame (received data)
Identifier
= "SV"
Version
= 1
Command
= 83h
Sequence number = 1
Response ID
= 1234
Access size
= 10
Status
= 0000h
Figure 8.7. Message Transmission