Check Your Package Thank you for purchasing the CONTEC product. The product consists of the items listed below. Check, with the following list, that your package is complete. If you discover damaged or missing items, contact your retailer. Product Configuration List - Product [CPS-PCS341EC-DS1-1201]…1...
No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this document.
Maintenance Connector ......................... 24 Power Connector (24VDC) ......................24 LED Indicator ..........................25 Rotary Switch ..........................26 Isolation Digital Input/ Digital Output Connector (DIO0, DIO1, DIO2, DIO3) ......26 LAN Port (LAN A, LAN B) ......................27 CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 6
RS-232C Interface (COM) ......................29 System Reference Specification ............................31 Power Requirements ........................33 Physical Dimensions ........................34 Appendix Battery ..............................35 List of Optional Products DIN Rail Fitting Power Supply ...................... 37 Stacking Type Modules ........................37 CPS-PCS341EC-DS1-1201 Hardware Manual...
The product contains the ARM®Cortex®-A8 processor (600MHz) and the DDR3 512MB system memory. - Decrease malfunctions or damages by bus isolation and surge protection. (Digital input/output) Electrical isolation between the digital input/output and CPU can block up the electrical noise flow. CPS-PCS341EC-DS1-1201 Hardware Manual...
- No electrolytic capacitor Without an electrolytic capacitor, which has a limited life, we are creating the product with a longer life. How to use Visit our website for the CPS-PC Series system setup guide. (http://www.contec.com) CPS-PCS341EC-DS1-1201 Hardware Manual...
You can download updated driver software and differential files as well as sample programs available in several languages. Note. For product information Contact your retailer if you have any technical question about a CONTEC product or need its price, delivery time, or estimate information. Limited Two-Year Warranty CONTEC products are warranted by CONTEC CO., LTD.
- Do not use or store this product in the presence of chemicals. - CONTEC reserves the right to refuse to service a product modified by the user. - In the event of failure or abnormality (foul smells or excessive heat generation), unplug the power...
Page 11
- To avoid electric shock, please do not touch the system with a wet hand. - The specification of this product is subject to change without notice for enhancement and quality improvement. Even when using this product continuously, be sure to read the manual of CONTEC’s website and understand the contents.
Page 12
1 Before Using the Product CPS-PCS341EC-DS1-1201 Hardware Manual...
Figure 2.1. Unlock the fixed hook-1 < 1 / 2 > (2) By using the screwdriver as leverage, move it upward in the direction of the arrow to unlock. Projection Tip Figure 2.1. Unlock the fixed hook-1 < 2 / 2 > CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 14
The point of the screwdriver Figure 2.2. Unlock the fixed hook-2 < 1 / 2 > (2) Rotate the screwdriver 90-degree in either direction. The point of the screwdriver Figure 2.2. Unlock the fixed hook-2 < 2 / 2 > CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 15
Figure 2.3. Mount the product on the DIN Rail < 2 / 3 > (3) Push up the hook to lock. Figure 2.3. Mount the product on the DIN Rail < 3 / 3 > CAUTION Confirm whether the product has been securely mounted onto the DIN rail. CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 16
Figure 2.4. Remove the product from the DIN Rail < 1 / 2 > (2) Pull the lower part of the product toward you and lift it up to remove. Figure 2.4. Remove the product from the DIN Rail < 2 / 2 > CPS-PCS341EC-DS1-1201 Hardware Manual...
Long-term usage might increase the temperature and lead to a malfunction or other troubles. - When using the product in a high temperature environment, its life time will be shorten. Perform the forced air cooling to counteract. CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 18
Figure 2.6. Spaces between the product and surrounding objects (exemplar) With the stacking device(s) 50mm 50mm 50mm *The measurement points are shown as the circles in the figures above. Figure 2.7. Spaces between the product and surrounding objects (exemplar) CPS-PCS341EC-DS1-1201 Hardware Manual...
(3) Engage the rail on the left side of the stacking module with the rail on the right side of the mounted product or of the other modules. Then, slid the module all the way toward the DIN rail. Figure 2.8. Affixing the stacking module < 3 / 5 > CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 20
(4) Lock the hooks of the stacking module. Figure 2.8. Affixing the stacking module < 4/ 5 > (5) Put back the end cover to the module. Figure 2.8. Affixing the stacking module < 5 / 5 > CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 21
(2) Unlock the fixed hooks of the module. Figure 2.9. Detaching the stacking module < 2 / 3 > (3) With the hooks unlocked, pull the module toward you. Figure 2.9. Detaching the stacking module < 3 / 3 > CPS-PCS341EC-DS1-1201 Hardware Manual...
For wiring, strip off the covered part of a wire rod (9 - 10mm approx.) and insert it to the opening. After the insertion, secure the wire rod with a screwdriver. Compatible wires are AWG 28 - 16. CAUTION Removing the connector plug by grasping the cable can break the wire. 9~10mm approx. Figure 2.10. Cable connection CPS-PCS341EC-DS1-1201 Hardware Manual...
In addition, the power supply must fulfill the following requirements. - Rising time for up to 24 voltage: 2 milliseconds up till 30 milliseconds Recommended power supply is CPS-PWD-90AW24-01 (by CONTEC). CAUTION If the maximum output current of the external power supply is smaller than the maximum consumption current of this product, the abnormal operations might occur due to the inrush current at the start-up time or the load fluctuation.
(Clear to Send) (Data Terminal Ready) (Data Set Ready) (Signal Ground) External device Figure 2.11. Example connection to a modem External device Figure 2.12. Example connection to a PC External device Figure 2.13. Example connection to a device CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 25
See the table below for baud rate that you can set with this product. Table 2.1. Baud Rate List Baud Rate(bps) Error(%) 0.00 0.00 0.00 1,200 0.00 2,400 0.00 4,800 0.00 9,600 0.16 14,400 0.16 19,200 0.16 28,800 0.16 38,400 0.16 57,600 0.16 115,200 0.16 CPS-PCS341EC-DS1-1201 Hardware Manual...
Opto-coupler Minus common Figure 2.14. Digital input circuit Example of connecting the product to an external device This Product +12V Input pin Sink type output Minus common Figure 2.15. Connecting the input to the sink type output CPS-PCS341EC-DS1-1201 Hardware Manual...
12 - 24 VDC The corresponding LED will be lit up when you output “1” into the appropriate bit. The corresponding LED will be turned off when you output “0” into the appropriate bit. Figure 2.17.Example connection to the LED CPS-PCS341EC-DS1-1201 Hardware Manual...
This Product Output pin(+) External power supply Minus common Source output acceptable input Figure 2.19. Connecting the output to the source output acceptable input Software Setup Visit our website for the CPS-PC Series system setup guide (http://www.contec.com). CPS-PCS341EC-DS1-1201 Hardware Manual...
⑩ ⑪ ⑫ ⑬ Figure 3.1. CPS-PCS341EC-DS1-1201 Stack Bus: Used for the stacking device power supply and communication. Maintenance Connector: Please do not use it. Power Connector: Use the 3-pin connector, included in this package. LED 1: Indicates the status of the product.
Please do not use it. Power Connector (24VDC) Use the 3-pin connector, included in this package. Connector type: by PHOENIX CONTACT, MC 1, 5/3-ST-3, 5 (or equivalent) Table 3.1. Power connector Pin No. Signal name V+(24VDC) V-(GND) CPS-PCS341EC-DS1-1201 Hardware Manual...
It will flash when sending data by the RS-232C. COM -TX(Green) It indicates no data sending by the RS-232C. Flashing It will flash when receiving data by the RS-232C. COM -RX(Green) It indicates no data receiving by the RS-232C. CPS-PCS341EC-DS1-1201 Hardware Manual...
This indicates the I/O signals. It connects output signals as digital input, DIO2 and connects input signals as digital output from other devices. This indicates the I/O signals. It connects output signals as digital input, DIO3 and connects input signals as digital output from other devices. Not connected CPS-PCS341EC-DS1-1201 Hardware Manual...
Indicates that LAN port is connected by 10Mbps or not connected. Indicates that LAN port is connected. Flashing Indicate that LAN port is transmitting and receiving data with the Link /Act(Green) connected external device Indicates that LAN port is not connected. CPS-PCS341EC-DS1-1201 Hardware Manual...
The product has 1 port of USB interface of TYPE-A. Table 3.7. USB connector Signal Name Pin No. USB_VCC DATA- DATA+ USB_GND CAUTION If you use the USB device with bus power, the ambient temperature should be lower than 55 °C. CPS-PCS341EC-DS1-1201 Hardware Manual...
Signal Pin No. Meaning Direction name Carrier detection Input Received data Input Transmitted data Output Data terminal ready Output Signal ground ----- Data set ready Input Request to send Output Clear to send Input Ring indicate Input CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 36
3 Nomenclature and Functions CPS-PCS341EC-DS1-1201 Hardware Manual...
Connector Standard SD standard follow Connector SD Memory card slot SD Card Slot Read/Write (Green) Baud Rate 300 - 115.2kbps Isolation/Voltage Resistance Non-isolated The Number of Channels RS-232C Connector 9-pin D-SUB Connector (Male) Transmission (Green), Reception (Green) CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 38
44.7 (W)×94.7(D)×124.8(H) (not include projection) Weight 300g Installation Method Quick mounting to 35mm the DIN rail Linux kernel 3.2 *1 Data “0” corresponds to High level and Data “1” corresponds to Low level. *2 Use power cable within 3meters. CPS-PCS341EC-DS1-1201 Hardware Manual...
- When you restart the power, give the product for at least one second (or more) of the power OFF time. - When you use with the CPS-PWD-90AW24-01(by CONTEC), instantaneous voltage drop allowed time will be 20 millisecond or less.
(1) Stick a slotted screwdriver through one of the openings (see the figure) to lift off the cover. Openings for a driver to stick through Figure 5.1. Remove the battery 1 (2) Remove the top cover. Figure 5.2. Remove the battery 2 CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 42
Cut the two holding metals with nippers and take off the battery. Button-type battery Holding metals Figure 5.4. Remove the battery 4 -Disposing the battery When disposing the battery, please comply with your local municipal regulations and ordinances. CPS-PCS341EC-DS1-1201 Hardware Manual...
- CPS-COM-2PD : with RS-422A/485 (2 ports) - CPS-AI-1608LI : with analog input - CPS-AO-1604LI : with analog output - CPS-SSI-4P : with temperature sensor input (http://www.contec.com) * Visit the Contec website regarding information on the optional products. CPS-PCS341EC-DS1-1201 Hardware Manual...
Page 44
3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan Japanese http://www.contec.co.jp/ English http://www.contec.com/ Chinese http://www.contec.com.cn/ No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. [01222016] [01222016] Management No NA04696 Parts No.
Need help?
Do you have a question about the CPS-PCS341EC-DS1-1201 and is the answer not in the manual?
Questions and answers