Power Supply Ratings; Operating And Storage Temperatures - Quectel EC21 Series Hardware Design

Lte standard module
Hide thumbs Also See for EC21 Series:
Table of Contents

Advertisement

5.2. Power Supply Ratings

Table 43: Power Supply Ratings
Parameter
Description
VBAT_BB and VBAT_RF
VBAT
Voltage drop during burst
transmission
Peak supply current
I
VBAT
(during transmission slot)
USB_VBUS
USB connection detection

5.3. Operating and Storage Temperatures

The operating and storage temperatures are listed in the following table.
Table 44: Operating and Storage Temperatures
Parameter
Operating Temperature Range
Extended Temperature Range
Storage Temperature Range
10
Within operation temperature range, the module is 3GPP compliant.
11
Within extended temperature range, the module remains the ability to establish and maintain a voice, SMS, data
transmission, emergency call*, etc. There is no unrecoverable malfunction. There are also no effects on radio spectrum
and no harm to radio network. Only one or more parameters like P
tolerances. When the temperature returns to the normal operation temperature levels, the module will meet 3GPP
specifications again.
EC21_Series_Hardware_Design
Conditions
The actual input voltages
must be kept between the
minimum and maximum
values.
Maximum power control
level on EGSM900
Maximum power control
level on EGSM900
-
Min.
10
-35
11
-40
-40
LTE Standard Module Series
Min.
3.3
-
-
3.0
Typ.
Max.
+25
+75
-
+85
-
+90
might reduce in their value and exceed the specified
out
Typ.
Max.
Unit
3.8
4.3
V
-
400
mV
1.8
2.0
A
5.0
5.25
V
Unit
ºC
ºC
ºC
87 / 118

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents