Show Control Operation
Show control is achieved by connecting a "Dry" or zero voltage contact to the show control terminals. The
Power Fog Industrial 9D requires no power to signal the fog, only one set of contacts that close for the
entire fogging cue.
For Show Control Operation, the DMX Address must be set on 555. Closing the Show Control Remote
terminals with dry contacts, triggers the following machine functions:
C + 1 = Fog On/ Off w/ Variflow
C + 2 = ECLIPSE On
C + 3 = Air Option
Disconnecting the G3000/PFI9D and Eclipse
1)
Close the CO2 tank valve (and pressure builder valve if using a Dewar tank)
2)
Turn on the Eclipse only to run out the CO2 from the lines and Eclipse valve.
This may take several cycles of the Eclipse to purge the line. Do no make fog at this time.
When the hissing noise stops is an indicator that the lines are now empty.
3)
With Caution disconnect the CO2 hose from the tank and Eclipse.
4)
Disconnect the cable from the fog machine to the Eclipse.
5)
Drain any condensate which has accumulated in the Eclipse.
15
www.ultratecfx.com