Show Control Operation; Optional Timer/ Duration Remote Operations; Timer/ Duration Remote Led Indicator - Ultratec LSG PFI-9D Operator's Manual

Lsg low smoke generator w/ power fog industrial 9d
Table of Contents

Advertisement

Show Control Operation

Show control is achieved by connecting a "Dry" or zero voltage contact to the show
control terminals. The Power Fog Industrial requires no power to signal the fog, only one
set of contacts that close for the entire fogging cue.
For Show Control Operation, the DMX Address must be set on 555. Closing the Show
Control Remote terminals with dry contacts, triggers the following machine functions:
C + 1 = On/ Off w/ Variflow
C + 2 = LSG On
C + 3 = Air Option

Optional Timer/ Duration Remote Operations

The Timer/ Duration Remote offers Duration, Interval, Variflow and fog on/ off controls.
Timer/ Duration Remote LED
Indicator
The Timer/ Duration Remote Handset was designed to
Duration
Interval
indicate operation modes. These are as follows:
Slow Flashing Light: Indicates unit is not ready to
operate but still in heating mode, fog is not available at
Variflow
this point.
Manual Fog
LED
Quick Flashing Light: Indicates unit is ready to operate
On/ Off Switch
but still in heating mode, some fog is available at this
point.
Solid Light: Indicates that the unit is ready to fog at full
output.
No Light: Indicates problems; a loss of power or remote is not connected. If these fail to correct the problem, contact
your local Ultratec Special Effects dealer.
Note: To operate the LSG MK II using the Timer/ Duration Remote, the DMX Address must be set on 555 and the
Duration control set over 50%. If the Duration is set at anything less than 50%, the Switched Power Port will be off.
The Interval Knob works in the same fashion for machines equipped with the Air Option. The Show Control Remote
and Timer/ Duration Remote cable may be extended from the machine and operated effectively away from the Power
Fog Industrial. The maximum recommended cable length is 225 Feet.
12