Operating Procedure; Digital Remote Operation - Ultratec G3000 Mega Fog Burst Operator's Manual

Hide thumbs Also See for G3000 Mega Fog Burst:
Table of Contents

Advertisement

Operating Procedure

Digital Remote Operation.

1) Adjust the remote flow rate "D" (demand) using + and – buttons to
desired fog output level.
2) To set the cycle time of the effect, press the menu button on the
G3000 to "Set Cycle On". If a preset cycle time is not required, set
value to 0:01 and press menu to select and go to the next screen.
3)
To "Set Cycle Off" time, enter value a value to represent the
duration of the effect. If a cycle time is not required, set the value to
0:00 and press the menu to select and go to the next screen.
4) LSG PRE FOG TIME or CO2 PRE FOG TIME: When using the
remote, a minimum time of 0:01 is needed to turn on the Mega Fog
burst (auxiliary output).
5) Press Menu button again to change screen to DMX menu, and
press Menu button again for Low Fluid Stop menu. Set Low Fluid Stop to "Off" or "On" if needed. When
set to "On" the fluid pumps will stop automatically when a low fluid level is detected when the fluid
bottle is in the jug holder. TECH TIP: Leave the setting at "Off" when using a G3000 with a 5'
industrial hose.
6) Press Menu button again to change screen to next menu selection. Screen will be back to main menu.
Ensure that fog machine is fully heated by looking at the right side of the screen. The temperature bar
graph will be to the top and the letter H in the bottom right will no longer be displayed. Press I/O button
to turn fog output "On" or "Off".
7) The PRE-FOG TIME that was set will show up in the bottom left side and start to count down. The
letter "R" will show up on the bottom right side of the screen.
8) Once the PRE-FOG TIME countdown reaches 0:00, the fluid pumps will start at the set flow rate
(Demand). Fog will start to flow out the G3000/Mega Fog Burst.
Note: The Mega Fog Burst Valve will open as soon as the PRE-FOG TIME counter starts.
9) If you have set the ON / OFF cycle timers mentioned previously, the next time that is displayed in the
bottom left of the screen will be first be the ON time and once that reaches 0:00 the next time that is
shown is the OFF time at which point the fluid pumps will stop and the Mega Fog Burst will turn Off.
Once the Off time reaches 0:00 the time will switch back to the PRE-FOG TIME again and the whole
process starts over again. (Step 7).