Sony DCR-TRV725E Service Manual page 162

Digital video camera recorder
Hide thumbs Also See for DCR-TRV725E:
Table of Contents

Advertisement

3. Switching Position Adjustment (VC-262 board)
RadarW
RadarW
RadarW
To obtain normal playback waveform output during the Digital8
playback mode, adjust the switching position.
Mode
VTR playback
Signal
SW/OL reference tape (WR5-2D)
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified Value
00
Adjusting method:
Order Page Address Data
1
2
0
01
01
3
3
21
4
3
01
0D
5
3
02
6
3
03
7
C
10
8
0
01
00
Note 1: If the data of page: 3, address: 21 is "72", the tape top being played.
After playing the tape for 1 to 2 seconds, stop it, perform step 4
and higher.
Note 2: If bit 0 of the data is "1", the A channel is defective. If bit 1 is "1",
the B channel is defective. Contents of the defect is written into
page: C, addresses: 10 and 12. See the following table. (For the bit
values, refer to "5-4. SERVICE MODE", "4-3. 3. Bit value
discrimination". ) If bit3 of the data is "1", the tape end being
played, and adjustment has errors.
Note 3: If the data is "EE" rewind the tape and repeat steps 1 to 7.
When the A channel is defective
Data of page:C,
Contents of defect
address:10
EE
Writing into EEPROM (IC4502) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC3301
(CAIN)
When the B channel is defective
Data of page:C,
Contents of defect
address:12
E8
Adjustment data is out of range
E7
No data is returned from IC3301
(CAIN)
Procedure
Insert the SW/OL reference tape
and enter the VTR STOP mode.
Set the data.
Check that the data is "02".
(Note1)
Set the data, and press PAUSE
button.
Check that the data changes to
"00".
Check that the data is "00".
(Note2)
Check that the data is other than
"EE". (Note3)
Set the data.
4. AGC Center Level and APC & AEQ Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
4-1. Preparations before adjustments
Mode
Subject
Note: Use a Hi8 MP tape.
Adjusting method:
Order Page Address Data
1
0
01
2
8
2A
3
4-2. AGC Center Level Adjustment (VC-262 board)
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note 1: Connect a 75Ω resistor between Pin qh and Pin 6 (GND) of CN1108.
75Ω resistor (Parts code: 1-247-804-11)
Adjusting method:
Order Page Address Data
1
2
0
01
3
2
2E
4
3
33
5
6
3
01
7
3
02
8
3
03
9
Note 2: If the data of page: 3, address: 03 is other than "00", adjustment
has errors.
Pin qh
Pin qd
5-47
Camera recording
Arbitrary
Procedure
01
Set the data.
C8
Set the data.
Record the camera signal for three
minutes.
Playback
Recorded signal at "Preparations
before adjustments"
Pin qh of CN1108 (RF MON) (Note 1)
Ext. trigger: Pin qd of CN1108 (DV RFSWP)
Oscilloscope
C
1E
The data of page: 3, address: 03 is "00"
Procedure
Playback the recorded signal at
"Preparations before adjustments"
01
Set the data.
01
Set the data.
08
Set the data.
Confirm that the playback RF
signal is stable. (Fig. 5-3-4.)
23
Set the data, and press PAUSE button.
Check that the data is "00".
Check that the data is "00".
(Note2)
Perform "APC & AEQ Adjustment".
PB RF signal is stable
13.3 msec
Fig. 5-3-4.