  • Page 1 User manual IES618-4D series Managed Industrial Ethernet switch User manual Version 1.0.0, July. 2013 www.3onedata.com.cn - 1 -...
  • Page 2 User manual IES618-4D series user manual Statement Copyright Notice Information in this document is reserved by 3onedata Co.,Ltd. Reproduction and extract without permission is prohibited. Trademarks Notice is registered trademarks of 3onedata Co.,Ltd. All other trademarks or registered marks in this manual belong to their respective manufacturers.
  • Page 3: Table Of Contents

    CHAPTER 3 APPEARANCE AND DIMENSION ............... 12 3.1 A ..........................12 PPEARANCE 3.2 D ........................... 13 IMENSION CHAPTER 4 PACKLING LIST ..................... 14 CHAPTER 5 CONFIGURE IES618-4D SERIES ETHERNET SWITCH ........ 15 5.1 M ........................15 ODIFY ADDRESS 5.2 L ........................16 OGIN ERVER 5.3 I...
  • Page 4 User manual 5.10 T ........................48 RAFFIC TATISTICS 5.10.1 RX frame statistics ..........................48 5.10.2 TX frame statistics ..........................48 5.11 N ......................... 49 ETWORK IAGNOSIS 5.11.1 Port mirroring ............................49 5.12 B .......................... 50 ASIC SETTINGS 5.12.1 Device address ............................50 5.12.2 System identification ...........................
  • Page 5: Chapter 1 Summarize

    User manual CHAPTER 1 SUMMARIZE 1.1 Introduction IES618-4D series is a industrial, management, redundant industrial Ethernet switch and integrate 4 port serial device server. It included 1. IES618-4D(RS-232)-P(12/48VDC), Support 8 port 10/100Base T(X) and 4 port RS-232, 2. IES618-4DI(RS-485)-P(12/48VDC), Support 8 port 10/100BaseT(X) and 4 port RS-485/422, 3.
  • Page 6 User manual  Serial port support adaptive function(Realcom)  Support WEB configuration,CLI command line,Telnet management function  2K MAC address table  Support power reverse connection protection.  Support redundant power supply , delay alarm output , heat radiation naturally and LED indicator front and back ...
  • Page 7: Chapter 2 Hardware Description

    User manual CHAPTER 2 HARDWARE DESCRIPTION 2.1 Panel design IES618-4D(RS-232)-P(12/48VDC Front panel Back panel Top panel Bottom panel 1. PWR1/PWR2 power input 2. Ground screw 3. Relay output terminal block 4. DIP switch 5. DIN-Rail mounts 6. CONSOLE port 7. RS-232 serial port 8.
  • Page 8 User manual 1. PWR1/PWR2 power input 2. Ground screw 3. Relay output terminal block 4. DIP switch 5. DIN-Rail mounts 6. CONSOLE port 7. RS-485/422 serial port 8. 10Base-T /100Base-TX port 9. LED indicator IES618-2F-4D(RS-232) -P(12/48VDC Front panel Back panel Top panel Bottom panel 1.
  • Page 9 User manual IES618-4F-4DI(RS-485)-P(12/48VDC Front panel Back panel Top panel Bottom panel 1. PWR1/PWR2 power input 2. Ground screw 3. Relay output terminal block 4. CONSOLE port 5. DIP switch 6. DIN-Rail mounts 7. 10Base-T /100Base-TX port 8. RS-485/422 serial port 9.
  • Page 10: Power Supply Input

    User manual 5. DIP switch 6. DIN-Rail mounts 7. 10Base-T /100Base-TX port 8. RS-232 serial port 9. 100Base-FX port 10. LED indicator IES618-2F-4DI(RS-485)-P(12/48VDC Front panel Back panel Top panel Bottom panel 1. PWR1/PWR2 power input 2. Ground screw 3. Relay output terminal block 4.
  • Page 11: Relay Connection

    User manual 2.3 Relay connection The relay owns two contacts of the terminal block on the top pane of IES618-4D series. It is used to detect both power failure and port failure. The two wires attached to contacts form an open circuit when: (1) IES618-4D series has lost power supply from one of the DC power inputs.
  • Page 12: Serial Port Connection

    User manual Note: ―TX±‖Transmitting data±, ―RX±‖receiving data±, ―—‖no use MDI(straight-through cable) : MDI-X(Cross over cable) : 100Base-FX fiber port 100Base-FX port works with full-duplex, SM or MM SC/ST optional. The fiber port must be used in pair, TX (transmitting) port connects remote switch‘s RX (receive) port; RX (receiving) port connect remote switch‘s TX (transmitting) port.
  • Page 13: Led Indicator

    User manual — DB9 Male(RS-232) RS-485 Serial port: RS-485 RS-422 Serial port: RS-422 RS-485/422 2.7 LED Indicator Indicator Description P1 connection regularly PWR1 P1 Power supply have no connection or unwonted P2 connection regularly PWR2 P2 Power supply have no connection or unwonted ON/OFF Device unwonted Flashing...
  • Page 14: Installation

    User manual Flashing Network in activity statues Did not established effective network connection Flashing In receiving data None data receive Flashing In transmitting data None data transmit 2.8 Installation Before installation, confirm that the work environment meet the installation require, including the power needs and abundant space.
  • Page 15 User manual the inlet and outlet holes. Cables should be banded and fixed when they are out of the groove; 7. User cable should be separated from the power lines. Cables, power lines and grounding lines cannot be overlapped and mixed when they are in the same groove road. When cable is too long, it cannot hold down other cable, but structure in the middle of alignment rack;...
  • Page 16: Chapter 3 Appearance And Dimension

    User manual Chapter 3 Appearance and Dimension 3.1 Appearance IES618-4D series...
  • Page 17: Dimension

    User manual 3.2 Dimension...
  • Page 18: Chapter 4 Packling List

    Please check the packaging and accessories by your first using. Please inform us or our distributor if your equipments have been damaged or lost any accessories, we will try our best to satisfy you. Quantity Description 3onedata Industrial Ethernet switch User manual Warranty card Product Qualified Card...
  • Page 19: Chapter 5 Configure Ies618-4D Series Ethernet Switch

    IES618-4D series Web interface through internet explorer, the IP address of IES618-4D series and PC must be in the same Local Area Network. You can modify PC's or IES618-4D series's IP address to make sure that they are in the same Local Area Network. Operating process can follow method 1 or method 2 as below, Method 1: Modify PC's IP address ...
  • Page 20: Login Webserver

    : Before entering the IES618-4D series switch WebServer, you must delete temporary IE files, and clear IE history, or perhaps because IE cookies due to an unknown error. The user name and password are case sensitive. Such as unclear devices IP address, can be obtained through the Blue_eyes...
  • Page 21: Introductuin Configure Interface

    User manual 5.3 Introduction configure interface The Web configuration page is divided into: 1 titles, 2 main menu, 3 configuration menu bar area three parts. Click the menu item in the menu bar, you can enter the corresponding configuration interface, display device state information and data configuration.
  • Page 22: System Status

    3onedata Co., Ltd. the registered trademark, the upper right corner of display is the current time, as shown in figure 5.3.2 show: (Figure 5.3.2)...
  • Page 23: Port Information

    5.3.2.2 Port information IES618-4D series a total of 8 ports, ports can confirm whether the port with the equipment complies with the information bar. Equipment at work, via the port status of the port information in the status view, for example in the figure below you can see port 4 is LINK and port connection status status as FULL, speed is 100M and port type for the TX(RJ45).
  • Page 24 1-500 Character delay(ms) data to Ethernet data Enter into IES618-4D series WEB interface, knock[Serial Server/COM settings], Please choice necessary configuration in drop down list, the serial configuration interface is as follows: (Figure 5.4.1) Configuration option: [Baud rate], [Parity], [Data Bits], [Stop Bits], [Max Frame Space], [Character Delay]...
  • Page 25: Configure Working Mode

    User manual The wait time when serial interface send data do not 1 data frames. If up to this time and do not have data, then send automatic. Can configure 1-500. [COM mode] Web interface default work mode if up to the model name, if the product is RS-485, it is RS-485 or RS422, If the product is RS-232, it is RS-232 5.4.2、Configure working mode Working mode configuration menu:...
  • Page 26 [Local port] IES618-4D series provided TCP port can be connect by other TCP/IP node, the TCP port have the relationship with the IES618-4D series‘s relevant serial interface. The figure as follows is TCP Server setting interface, Session 1 set local port is 30000, external TCP port connect IES618-4D series through this port.
  • Page 27 User manual 3.UDP Under the UDP work mode. IES618-4D is server and also client, the relevant setting is ―Local port‖, ―Target address‖ and ―Target port‖. It can support point to point and multicast UDP, setting method is the same as TCP. 4.TCP Auto In this Mode, serial device server can act as server or client.
  • Page 28: Serial Port Information

    User manual (Figure 5.4.5) 1. Address pool just support Type A and type B address 2. Start address and end address must in the network segment. 3. Start address value must less than or equal to end address. 5.4.3. Serial port information It main function of serial port information: Display incorrect data statistics and connection information that send by serial port.
  • Page 29 User manual Select auto-negotiation, speed, and duplex auto-negotiation. Configuration Items Description Port Port name, corresponding to mark in panel. Type Display port type (TX or FX). Speed Display configurable speed of port or auto-negotiation mode. Auto-negotiation (AUTO) ,full duplex (FULL) , half duplex (HALF) optional, default Duplex mode is auto-negotiation mode.
  • Page 30: Bandwidth Management

    User manual (Figure 5.5.2) : 1. When one end is auto-negotiation, and the other end to force rate setting, according to the Ethernet standard consultation rate for corresponding obligatory rate for half-duplex mode 2. Port flow control auto-negotiation mode can be set only when other modes cannot be set 3.
  • Page 31 User manual 4M, 8M.The rate of normal priority queues(N) is 1 or 2 times as wide as that of low priority queues. The rate of medium priority queues(M)is 1 or 2 times as wide as that of normal one. The rate of high priority queues is 1 or 2 times as wide as that of medium one.
  • Page 32: L2 Features

    User manual 5.6 L2 Features 5.6.1 VLAN 5.6.1.1 Based on port VLAN Port VLAN provides a solution that can divide the ports of switch into different virtual private domain. The data cannot be exchanged in the different private domain, so it's more secure to maintenance. About port VLAN,different VLAN with different identity.
  • Page 33 0xFFF are reserved. All other values may be used as VLAN identifiers, allowing up to 4,094 VLAN. 1. The type of port’s Line IES618-4D series support 2 type port lines: Access: Port belongs to 1 VLAN, normally, it used for connecting user device, default all port is access port.
  • Page 34 User manual Trunk, member type: Tagged. (Figure5.6.1) We can know as the figure, the type of port 7, 8 is Trunk, can allow the data of VLAN 1 and VLAN 2 pass. 5. Modify VLAN It can re-configure existing VLAN including modifying member‘s type and quantity of the port. Steps are as follows: 1.
  • Page 35: Static Filtering

    User manual 2. The port that already set in ring network port, the VLAN port type must Trunk and takes Tag, figure as 5.6.4. (Figure 5.6.4) 8. Typical VLAN Configuration Suppose switch‘s port 3, 4, 5 satisfied to the requirements as follows: port 3 can intercommunicate with Port 5, Port 4 can intercommunicate with Port 5, Port 3 can‘s intercommunicate with Port 4, How to set VLAN? (Not consider the configuration of other VLAN) Let‘s...
  • Page 36: Qos

    Static address is the MAC address does not age once it has been added, this address tables before being deleted remains in effect, and not be restricted by maximum aging time. IES618-4D series supports up to 15 static multicast filtering.
  • Page 37 User manual Users can select the QOS priority queue mechanism, the queue mechanism in two ways: weighted Fair mode and strict mode. Weighted Fair refers to this port sends message according to queue priority High, Medium, Normal and low in proportion of 8:4:2:1 when some ports traffic is heavy. If sending speed is less than bandwidth, the message of each priority queues can send normally;...
  • Page 38 User manual extending the frame size of the Ethernet standard by four bytes which was published as IEEE 802.3ac in 1998. The QoS technique developed by the working group, also known as class of service (CoS), is a 3-bit field called the Priority Code Point (PCP) within an Ethernet frame header when using VLAN tagged frames as defined by IEEE 802.1Q.
  • Page 39: Redundancy

    Ethernet switch, which can make you easily and conveniently establish redundant Ethernet, and can facilitate the quick recovery of any network section of automatic system disconnected from the network. IES618-4D series supports maximum 4 ring groups. Each group set up 2 ports as Ring Port and a port cannot belong to several rings.
  • Page 40 User manual receive it, then reply a confirm packet to ensure network connection is active. If this setting will influence self-recovery time, we suggest advanced users can use it. Basic interface of Rapid Ring as shown in figure 5.7.1: (Figure 5.7.1) Initial interface display redundancy protocol is none, can configure it through [Settings].
  • Page 41 User manual 2. Enable ring group 1(or group 2), input network ID (support 0-255 pure digital), select the ring port in ring port 7 and ring port 8, figure as 5.7.5. (Figure 5.7.5) Ring V2 can also set Hello_time . Hello_time setting is time interval of sending detecting packet to network at regular time.
  • Page 42 User manual as port 6 in ring group 2, network ID: 3, type: coupling ring, figure as 5.7.9. (Figure 5.7.9) 4. Set 107, 108, 109 device‘s ring port as port 7 and port 8 in ring group 1, network ID: 1, type: single ring. Set 102, 103, 104 device‘s ring port as port 7 and port 8 in group 1, network ID: 2, type: single ring.
  • Page 43 User manual (Figure 5.7.12) 3. Enable Ring Group 1(or Group 2), and enter into Network ID(support 0-255 number only).Select Ring Port between Port 7 and Port 8. (Figure 5.7.13) ―Chain‖ refers to strengthen user‘s capability of making any type of redundant topological structure with flexibility by taking an advanced software technology.
  • Page 44 User manual Operation method: 1. Select Ring V3, enable ring group 1 and 2. (Hello_time can be disable, if enable, time of sending Hello packet could not be very fast, it will influence CPU operate speed); 2. Set 105, 106 device‘s ring port as port 1 and port 2 in ring group 1, network ID: 1, type: single ring. Set ring port as port 4 in ring group 2, Coupling ctrl port: 2, network ID: 3, type: coupling ring, figure as 5.7.15.
  • Page 45: Rstp

    User manual Operating method: 1. Enable Ring Group 1: Hello time can be disable too, if it enable, time of sending Hello packet could not be very fast, or it will influence CPU dealing speed. 2. Set up Port 7 and 8 of Device 100, 101, 102 and 103 to be Ring Port in Ring Group 1, Network ID is1, Ring Type is Single;...
  • Page 46 User manual In 2001, the IEEE introduced Rapid Spanning Tree Protocol (RSTP) as 802.1w. RSTP provides significantly faster spanning tree convergence after a topology change, introducing new convergence behaviors and bridge port roles to do this. RSTP was designed to be backwards-compatible with standard STP.While STP can take 30 to 50 seconds to respond to a topology change, RSTP is typically able to respond to changes within 3 ×...
  • Page 47: Port Trunking

    User manual Directly connect terminal:connect the edge of network switch with terminal devices with configuration Edge port,which can achieve port state rapid conversion without the processing Discarding,Learning, Forwarding. Don’t join RST structure:don‘t participate in RSTP running. RSTP switch port states: 1.
  • Page 48: Access Profile

    User manual Pictured in via a link aggregation between two switches form a computer network, Configuring link aggregation functionality through Web pages below。As shown in Figure 5.7.22. (Figure 5.7.22) Device supported 3 trunking groups, operate method: choice apply, choice the port need to trunking the port list, Choice setting, available after reboot.
  • Page 49: Remote Monitoring

    User manual (Figure 5.8.1) 1.Please contact our online technical support if you forget login name and password 2. Set same user mane, the front settings of user name/password will be available. 5.9 Remote monitoring 5.9.1 SNMP management SNMP management 1. Introduction of SNMP SNMP (Simple Network Management Protocol) is an internet-standard protocol for managing devices on IP...
  • Page 50 User manual networks. It is used mostly in network management systems to monitor network-attached devices for conditions that warrant administrative attention. 2. Work Mechanism of SNMP SNMP includes 2 parts: NMS and Agent: NMS: Network Management Station. Software runs on the manager. The common management platforms are "Quid View", "Sun Net Manager"...
  • Page 51: Relay Alarm

    Power alarm IES618-4D series provided dual DC power supply (AC power supply did not have alarm), if one power supply had problem, another will support power supply immediately, dual power supply hot back -up. Select to enable power alarm, If power supply was in unusual status, device will send alarm signal, inform power supply work unusual.
  • Page 52: Traffic Statistics

    User manual In default status, the type of relay output is open, the alarm light is OFF, and have no alarm, relay alway open. When the device have alarm, the light is ON, relay close. 5.10 Traffic Statistics The function of traffic Statistics is to calculate the data packets in a fixed time, included transmit and receive data packets.
  • Page 53: Network Diagnosis

    User manual Number of successful output frames(the receiver is busy, but Deferred It sends successfully after a delay) OutFiltered Filtered frames output OutDiscards Discarded frames output(because of cache, flow control, etc.) 5.11 Network Diagnosis 5.11.1 Port mirroring Port mirroring refers to copy data from the port which need to be monitored to appointed monitoring port for analysis and monitoring.
  • Page 54: Basic Settings

    User manual 5.12 Basic settings 5.12.1 Device address Device address Device configuration support two modes, DHCP and static IP address, can get the device‘s IP address via client when the DHCP function is running, if you need NTP that need to connect internet, please enter the available and correct gateway and DNS address.
  • Page 55: System Identification

    In System Identification interface we can see Model, Name, Description, Serial NO., and Contact Information. We can modify these above items by this function. It will take effect after system reboot. Figure 5.12.3 is initial device settings of IES618-4D series switch. (Figure 5.12.3)...
  • Page 56 User manual (Figure 5.12.4) 1. Factory Default If you know the IP address of the device, user name and password: Use IE to login Web interface. Click "System Management" Click "System File Update" Choose "Factory Default" Click "OK" Notice: the IP address will be "192.168.1.254". Open a new interface, input "192.168.1.254"...
  • Page 57: System Logout

    User manual Use IE to login Web interface. Click "System Management" Click "System File Update" Choose "Upgrade Firmware" Click "Browse" and find the place of uploading the file. Click "Upgrade" A suggestion‖ interruption of power is not allowed during uploading‖ , confirm it. :...
  • Page 58: Chapter 6 Other Function Configure

    User manual Chapter 6 other function configure 6.1 DIP switch IES618-4D series have 4 DIP switch. Can default factory through DIP 3. DIP switch ON function Hold Factory default Hold Hold 6.1.1 Factory default Put the DIP switch 3 to ON, Power ON again, the default factory finished. After default factory, must put the DIP switch to OFF, otherwise, will default factory again when power ON next time.
  • Page 59: Appendix 1 Glossary Table

    User manual Appendix 1 Glossary table Glossary Description ARP (Address Resolution An IP address to physical address protocol Protocol) Auto-Negotiation Switches at both ends of the device in accordance with the maximum performance to auto-negotiate the speed and duplex mode Broadcast Storm A port send excessive broadcast frame meantime on the network, accumulate the respond to send messages on the network , consume...
  • Page 60: Appendix 2 Default Factory

    User manual Appendix 2 Default factory Main Menu Function Main Menu Name IES7110-2GS Module IES7110-2GS System System status Desription 3onedata information Serial No. Contact information sale@3onedata.com Port enable Enable Port Speed mode Consult automatic configuration Flow control enable Port Egress...
  • Page 61: Appendix 3 Treatment Of Common Problem

    User manual Appendix 3 Treatment of common problem 1. Why the page is not normal when configured by a web browser? Before the access to WEB interface, please clear the IE cache and cookies. Otherwise, the WEB interface may be not normal.

Table of Contents