User manual MES5000 series user manual Statement Copyright Notice Information in this document is reserved by 3onedata Co.,Ltd. Reproduction and extract without permission is prohibited. Trademarks Notice is registered trademarks of 3onedata Co.,Ltd. All other trademarks or registered marks in this manual belong to their respective manufacturers.
CHAPTER 1 SUMMARIZE 1.1 Introduction MES5000 series are industrial grade, managed and redundancy Ethernet switch. The series support 3 channel 4-port Fast Ethernet (copper ports and optical fiber port optional) module. MES5000-4GS-8T-16F supports 16-port 100 Base-FX, 4-port Gigabit SFP and 8-port 100 Base-TX.
10. 100M Base-FX port 11. 10/100M Base-T(x) port 12. Gigabit SFP port 2.2 Power supply input The MES5000 series rear panel provides 2-way 48VDC power input terminals or 2-way (36~72 VDC) 220VAC power input terminals. The first power input is a 5-pin 7.62mm pitch terminal with 3-pin terminals (90~264 VAC) for power input and 2-pin (R +, R-) terminals for relays output;...
User manual 2.4 Communication port 10Base-T /100Base-TX Ethernet port 10Base-T/100Base-TX Ethernet port is located on front panel and the type is RJ45. The pinout of RJ45 port connects to UTP or STP. The distance is not more than 100m. 100Mbps Ethernet connector takes 120Ωof UTP 5, 10Mbps Ethernet connector takes 120Ωof UTP 3, 4, 5.
User manual Suppose: If you make your own cable, we advise to label the two sides of the cable with the same letter (A-to-A and B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 1000Base-SFP fiber port(mini-GBIC) 1000Base-SFP fiber port adopts Gigabit mini-GBIC transmission, can choice different SFP module according to different transfer distance.
Page 9
User manual 4. Power: 48VDC (36~72 VDC) power input Or 220VAC (90~264 VAC) power input 5. Environment: Working temperature: -40~85℃ Storage temperature: -40~85℃ Relative humidity: 5%~95% Rack mount installation In most of industrial application, it is convenience to use rack mount installation, the step of installation is as follows: 1.
Please check the packaging and accessories by your first using. Please inform us or our distributor if your equipment have been damaged or lost any accessories, we will try our best to satisfy you. Quantity Description 3onedata Industrial Ethernet switch User manual Warranty card Product Qualified Card...
MES5000 series Web interface through internet explorer, the IP address of MES5000 series and PC must be in the same Local Area Network. You can modify PC's or MES5000 series's IP address to make sure that they are in the same Local Area Network. Operating process can follow method 1 or method 2 as below, Method 1: Modify PC's IP address ...
: Before entering the MES5000 series switch WebServer, you must delete temporary IE files, and clear IE history, or perhaps because IE cookies due to an unknown error. The user name and password are case sensitive. Such as unclear devices IP address, can be obtained through the Blue_eyes...
User manual 5.3 Introduction configure interface The Web configuration page is divided into: 1 titles, 2 main menu, 3 configuration menu bar area three parts. Click the menu item in the menu bar, you can enter the corresponding configuration interface, display device state information and data configuration.
5.4.2 Port information MES5000 series a total of 8 ports, ports can confirm whether the port with the equipment complies with the information bar. Equipment at work, via the port status of the port information in the status view, for example in the figure below you can see port 4 is LINK and port connection status as FULL, speed is 100M and port type for the TX(RJ45).
User manual 5.5 Port configuration 5.5.1 Port settings The port configuration interface mainly include port type (Electric port or optical port), setup speed mode and duplex mode, flow control. Only when the port is enabled for the port speed, duplex, flow control will work. Select auto-negotiation, speed, and duplex auto-negotiation.
User manual (Figure 5.5.2) : 1. When one end is auto-negotiation, and the other end to force rate setting, according to the Ethernet standard consultation rate for corresponding obligatory rate for half-duplex mode 2. Port flow control auto-negotiation mode can be set only when other modes cannot be set 3.
Page 19
User manual 3 Broadcast&Multicast only; 4 Broadcasts only ―----‖ stands for no limitation, the rate of low priority queues (L)can be set as :128k, 256k, 512k, 1M, 2M, 4M, 8M.The rate of normal priority queues(N) is 1 or 2 times as wide as that of low priority queues. The rate of medium priority queues(M)is 1 or 2 times as wide as that of normal one.
User manual If priority queue bandwidth configuration is available, must mark the enter into port‘s data pack as CoS. 5.5.3 Storm Suppression Broadcast storm is the accumulation of broadcast and multicast traffic on a computer network. Extreme amounts of broadcast traffic constitute a broadcast storm. A broadcast storm can consume sufficient network resources so as to render the network unable to transport normal traffic.
User manual 1. Add Item Group name can use any valid characteristic in port based VLAN. The same group name means you need to modify the members of the group. A new group name means the new transmission rule is built. The transmission item is not more than 32 in port based VLAN.
Page 22
User manual 0xFFF are reserved. All other values may be used as VLAN identifiers, allowing up to 4,094 VLAN. Main function of IEEE 802.1Q VLAN is the VLAN tag. The tag including VLAN information can insert in the Ethernet frame. The device transmits the data according its transmission rules. VLAN tag protocol in the data frame is 2 byte;...
Static address is the MAC address does not age once it has been added, this address tables before being deleted remains in effect, and not be restricted by maximum aging time. MES5000 series supports up to 15 static multicast filtering.
User manual 5.7 QoS QoS provides four internal queues, each queue supports four different levels of traffic, shorter persistence time of high-priority data packets in the switch, supports lower latency for certain delay-sensitive traffic. According to port ID, MAC address, 802.1p priority tags, DiONetServ and IP TOS, equipment can be abale to put the packets to an appropriate level.
Page 25
User manual new priority classes and Generic Attribute Registration Protocol (GARP) was not published separately but was incorporated into a major revision of the standard, IEEE 802.1D-1998. It also required a short amendment extending the frame size of the Ethernet standard by four bytes which was published as IEEE 802.3ac in 1998. The QoS technique developed by the working group, also known as class of service (CoS), is a 3-bit field called the Priority Code Point (PCP) within an Ethernet frame header when using VLAN tagged frames as defined by IEEE 802.1Q.
Ethernet switch, which can make you easily and conveniently establish redundant Ethernet, and can facilitate the quick recovery of any network section of automatic system disconnected from the network. MES5000 series supports maximum 4 ring groups. Each group set up 2 ports as Ring Port and a port cannot belong to several rings.
Page 27
User manual self-recovery time, we suggest advanced users can use it. Basic interface of Rapid Ring as shown in figure below: Initial interface display redundancy protocol is none, can configure it through [Settings]. Ring V3 supports Single ring, coupling ring, chain ring and Dual_homing. Ring V3 enable method: 1.
User manual (Figure 5.8.2) 3. Enable Ring Group 1 (or Group 2) , and enter into Network ID (support 0-255 number only) . Select Ring Port between Port 1 and Port 2. ―Chain‖ refers to strengthen user‘s capability of making any type of redundant topological structure with flexibility by taking an advanced software technology.
User manual (Figure 5.8.5) 105 switch belong to two different ring network group, so the network mark of ring network group must different. 5.8.1.3 Ring V3 Coupling Configuration Coupling ring structure figure as 5.8.6: Coupling(Figure 5.8.6) Operating method: 1. Enable Ring Group 1 and Ring Group 2; (Hello_time can be disable too, if it enable, time of sending Hello packet could not be very fast, or it will influence CPU dealing speed.);...
User manual (Figure 5.8.8) 4. Set up Port 1 and 2 of Device 107, 108, 109 to be Ring Ports in Ring Group 1, Network ID is 1, Ring Type is Single; Set up Port 4 and 5 of Device 102, 103, 104 to be Ring Port in Ring Group 1, Network ID is 2, Ring Type is Single.
User manual (Figure 5.8.10) 3. Use a wire to connect Port 7 and 8 of Device 107-109 in turn to make a chain. Use a wire to connect Port 7 and 8 of Device 100-103 in turn to make a Single Ring, Then use a wire to connect Port 8 of Device 107 and Port 7 of Device 109 to normal port of Device 102 and 103.
Page 32
User manual Rapid Spanning Tree of concepts: Switch priority:As the bridge priority,the bridge priority and bridge MAC address combine bridge ID, the smallest ID bridge will become the root bridge on the network. Polling interval:how often send BPDU packet at one time. Forwarding delay:the port state of switch remain a forward delay time over the listening and learning.
User manual 4. Forwarding- A port receiving and sending data, normal operation. RSTP still monitors incoming BPDUs that would indicate it should return to the blocking state to prevent a loop. The example of Configuration: The priority of network bridge is ―32768‖, If there did not have network ID less than itself, itself is root network bridge.
User manual 5.9 LLDP 5.9.1 Parameter Configuration LLDP is a second layer topology discovery protocol, the basic principle is: network equipment to the adjacent equipment issued its notice of state information, and each port of all equipment are stored with their own information, if a local device state changes, also can with its directly connected neighbor devices to send updated information to that neighbor devices will be the information stored in the standard SNMP-MIB library.
User manual 5.10.1 User password Enterprise usually required two different person to monitor device and manage system/ network. The authority need to separate. Monitor person was in charge of monitor work, system/network person was in charge of classification management: system/work management. The switch provided Administrator authority and Observer authority.
User manual example: If the device is a turn on DHCP Server functionality, 2 sets the static address table: 192.168.1.19 corresponds to port 1; 192.168.1.20 port 2. Unit b opens automatically obtain an IP address feature, if the device is connected to a port 1 device-b, device b to automatically obtain IP addresses 192.168.1.19;...
User manual security, the port will forward the data when the specified MAC make a connection with this port, it is assumed that to set port security and with one MAC binding, then this PC can communicate with other ports, but other computers connected to this port cannot communicate.
User manual MES5000 series supports SNMP V1/V2c. Both SNMP V1 and V2c use public character strings for match authentication. SNMP usually uses UDP Port 161(SNMP) and 162 (SNMP-traps) based on TCP/IP protocol. SNMP protocol agent is existed in network device. MIB (information specific to the device) is uses as device connector. These network devices can be monitored or controlled through the agent.
Power alarm MES5000 series provided dual DC power supply (AC power supply did not have alarm), if one power supply had problem, another will support power supply immediately, dual power supply hot back -up. Select to enable power alarm, If power supply was in unusual status, device will send alarm signal, inform power supply work unusual.
Page 40
User manual device will output a signal, inform the device work unusual. In default status, the type of relay output is open, the alarm light is OFF, and have no alarm, relay alway open. When the device have alarm, the light is ON, relay close.
User manual 5.12 Port Statistics The function of traffic Statistics is to calculate the data packets in a fixed time, included transmit and receive data packets. Operate method: Start to calculate after select clear 5.12.1 RX frame statistics Unicast Numbers of the unicast data packets received by the port Multicast Numbers of the multicast data packets received by the port Broadcast...
User manual SysbolErr Number of data packets which is incorrect, incomplete or including invalid characters (including FCS) between 64 bytes and 1518/1522 bytes (Enable VLAN) 5.12.2 TX frame statistics Unicast Numbers of the unicast data packets sent by the port Multicast Numbers of the multicast data packets sent by the port Broadcast...
User manual (Figure 6.10.1) Number of bytes of all data packets sent by the port Number of bytes of all data packets received by the port Unicast Number of unicast data packets sent and received by the port Multicast Number of multicast data packets sent and received by the port Broadcast Number of broadcast data packets sent and received by the port Error...
User manual Static authentication MAC address by configuring IEEE 802.1x authentication, the switch will not be aging. Regardless of the device is connected to the switch port happen to the MAC address table MAC address and port corresponding relationship always will not change, the relationship is completely controlled by the IEEE 802.1X authentication server.
User manual 1. This function is not often used. Otherwise other port-based higher management function like RSTP,IGMP SNOOPING 2. Port mirroring function can only deal with the normal FCS packets. It cannot deal with error data frames. 5.14 Basic settings 5.14.1 Log information The device provides system log for user's reference of troubles.
User manual Local Time To configure the time by hand to undated the time of the device Enable NTP To update the time of the device by using NTP protocol Time Zone Standard time zones could be defined by geometrically subdividing the Earth's spheroid into 24 lines. The local time in neighboring zones would differ by one hour.
Page 47
User manual available and correct gateway and DNS address. IP Address IP address is a address of 32 bits length which is assigned to the device on the internet. The IP address consists of two fields: the network number field (net-id) and the Host ID field (host-id). For can conveniently manage IP address, IP addresses are divided into five categories.
In System Identification interface we can see Model, Name, Description, Serial NO., and Contact Information. We can modify these above items by this function. It will take effect after system reboot. Figure below is initial device settings of MES5000 series switch. Name To give a name to each device, length is not more than 16 bytes.
Page 49
User manual 1. Factory Default If you know the IP address of the device, user name and password: Use IE to login Web interface. Click "System Management" Click "System File Update" Choose "Factory Default" Click "OK" Notice: the IP address will be "192.168.1.254". Open a new interface, input "192.168.1.254"...
User manual If you know the IP address of the device, user name and password: Use IE to login Web interface. Click "System Management" Click "System File Update" Choose "Upgrade Firmware" Click "Browse" and find the place of uploading the file. Click "Upgrade"...
Make a call to our technical office. Return or replace product. 6.1 Internet Service Please visit http://www.3onedata.com 6.2 Make a call to our technical office You can call our technical support office, the company has professional technical engineers to answer your questions and help you resolve your problems at the first time.
User manual Appendix 1 Glossary table Glossary Description ARP (Address Resolution An IP address to physical address protocol Protocol) Auto-Negotiation Switches at both ends of the device in accordance with the maximum performance to auto-negotiate the speed and duplex mode Broadcast Storm A port send excessive broadcast frame meantime on the network, accumulate the respond to send messages on the network , consume...
User manual Appendix 2 Treatment of common problem 1. Why the page is not normal when configured by a web browser? Before the access to WEB interface, please clear the IE cache and cookies. Otherwise, the WEB interface may be not normal.