Download Print this page

Sharp MX-FNX2 Service Manual page 52

Digital full color multifunctional system option saddle stitch finisher punch module paper pass unit

Advertisement

f. F1-11, Stack Delivery Motor (FAM) Fault
Cause/Trouble section
Delivery belt home position sensor
(FOBHPD)
Wiring
Stack delivery roller
Stack delivery motor (FAM), Finisher
controller PCB
g. F1-15, Lift Motor (FLM) Fault
Cause/Trouble section
Paper surface sensor (FSLD)
Tray up/down mechanism
Finisher controller PCB
Lift motor (FLM), Wiring
h. F1-15, Lift Motor (FLM) Fault
Cause/Trouble section
Tray position
Lift upper limit sensor (FULD)
Finisher controller PCB, Wiring
i. F1-15, Shift Motor (FLM) Fault
Cause/Trouble section
-
Finisher controller PCB
Tray up/down mechanism, lift motor
(FLM)
Lift motor lock (FLE), Finisher controller
PCB
j. F1-19, Alignment Motor (front) Fault
Cause/Trouble section
Alignment plate home position sensor
(front; FFJHPD)
Wiring
Alignment plate (front)
Alignment motor (front; FFJM), Finisher
controller PCB
k. F1-20, Alignment Motor (Rear; FRJM) Fault
Cause/Trouble section
Alignment home position sensor (rear;
FRJHPD)
Wiring
Alignment plate (rear)
Alignment motor (rear; FRJM), Finisher
controller PCB
MX-FNX2/AR-PN1/MX-RBX1 SELF DIAG MESSAGE AND TROUBLE CODE 9 – 5
Procedure
1
Check the delivery belt home position sensor (FOBHPD).
Is the sensor normal?
2
Is the wiring between the finisher controller PCB and the
stack delivery motor (FAM) normal?
3
Try turning the stack delivery motor (FAM) by hand.
Is the rotation smooth?
4
Try replacing the stack delivery motor (FAM).
Is the problem corrected?
Procedure
1
Check the paper surface sensor (FSLD).
Is the sensor normal?
2
Check the tray up/down mechanism. Is the mechanism
normal?
3
Is 24 VDC supplied from the finisher controller PCB to the lift
motor (FLM) as soon as the tray is driven?
4
Check the wiring from the finisher controller PCB to the lift
motor (FLM); is it normal?
Procedure
1
Is the tray as far as the lift upper limit sensor (FULD)?
2
Check the lift upper limit sensor (FULD). Is the sensor
normal?
3
Check the wiring from the finisher controller PCB to the lift
upper limit sensor (FULD); is it normal?
Procedure
1
Is the tray in UP position?
2
Is power supplied to the finisher controller PCB as soon as
the tray is driven?
3
Is there a fault in the tray up/down mechanism?
4
Check the lift motor lock sensor (FLE).
Is the sensor normal?
Procedure
1
Check the alignment home position sensor (front; FFJHPD).
Is the sensor normal?
2
Is the wiring between the finisher controller PCB and the
alignment plate motor (front; FFJM) normal?
3
Is there mechanical trapping in the alignment plate path?
4
Try replacing the alignment motor (front; FFJM).
Is the problem corrected?
Procedure
1
Check the alignment home position sensor (rear; FRJHPD).
Is the sensor normal?
2
Is the wiring between the finisher controller PCB and the
alignment motor (rear; FRJM) normal?
3
Is there mechanical trapping in the path of the alignment
plate?
4
Try replacing the alignment motor (rear; FRJM).
Is the problem corrected?
Check
Check
Check
Check
Check
Check
Result
Remedy
NO
Replace the sensor.
NO
Correct the wiring.
NO
Correct the mechanical
system.
YES
End.
NO
Replace the finisher
controller PCB.
Result
Remedy
NO
Replace the sensor.
NO
Correct the mechanism.
NO
Replace the finisher
controller PCB.
YES
Replace the lift motor (FLM).
NO
Correct the wiring.
Result
Remedy
YES
Lower the position of the
tray.
NO
Replace the sensor.
YES
Replace the finisher
controller PCB.
NO
Correct the wiring.
Result
Remedy
YES
Go to step 4).
NO
Go to step 2).
YES
Go to step 3).
NO
Replace the finisher
controller PCB.
YES
Correct the tray up/down
mechanism.
NO
Replace the tray up/down
motor.
YES
Replace the finisher
controller PCB.
NO
Replace the sensor.
Result
Remedy
NO
Replace the sensor.
NO
Correct the wiring.
YES
Correct the mechanical
system.
YES
End.
NO
Replace the finisher
controller PCB.
Result
Remedy
NO
Replace the sensor.
NO
Correct the wiring.
YES
Correct the mechanical
mechanism.
YES
End.
NO
Replace the finisher controller
PCB.

Advertisement

loading

This manual is also suitable for:

Ar-pn1aAr-pn1bAr-pn1cAr-pn1dMx-rbx1