Available languages

Problem
Auger System
Auger tension pulley arm return
spring broken or missing
Auger tension pulley arm stuck or
binding
Auger tension pulley arm or
pulley
misaligned or damaged
Auger belt broken,
Foreign material on pulleys and
or repeated failure
belt, oil, grease, dirt etc.
Auger pulleys misaligned, loose,
damaged or bent
Incorrect or damaged auger belt
Auger belt guide pin not adjusted
Auger rotating
when
auger control
Auger tension pulley arm return
handle released
spring broken or missing
Causes
Replace tension arm return spring
Repair or replace tension arm as necessary
Repair, replace or align tension arm and or
pulley as necessary
Clean belt and pulleys as necessary, replace
belt if necessary
Replace or align pulleys as necessary
Replace with correct size and type belt
Adjust belt guide pin to within 1/8 to 3/16 in.
from pulley. (Guide pin keeps belt in pulley
when disengaged)
Replace tension arm return spring
25
Remedy