14 Removing the housing

14 Removing the housing
4 Fan insert
37 Locking lever
1. Switch off mains fuse, secure and fit warning
sign.
2. Remove cover and upper part of housing.
3. Press locking lever slightly to the left (→ arrow
I), release and raise the fan insert slightly.
4. Press together locking tabs of stud and raise
fan insert slightly.
5. Press together locking tabs of stud and evenly
pull entire fan insert out of lower part of hous-
ing in parallel (→ arrows I - III).
6. Installation is carried out in reverse order.

15 Removal

Dismantling may only be undertaken by a
qualified electrician.
DANGER Danger to life from electric
shock.
Prior to accessing the connection terminals,
switch off all supply circuits. Switch off mains
fuse, secure against being accidentally switched
back on and position a visible warning sign.
1. Remove spiral housing.
2. Remove all cables.
3. Remove lower part of housing from the wall.
10
36 Locking tabs
38 Locking tabs
16 Environmentally responsible
disposal
The ventilation unit and the packaging contain
parts that can be recycled, and should not end up
in the domestic waste.
Dispose of the packaging material in an environ-
mentally-friendly way, in compliance with the reg-
ulations valid in the country where you are.
Dispose of the air filter in an environmentally-
friendly way, in compliance with the regulations
valid in the country where you are.
At the end of its service life, dispose of the unit in
an environmentally-friendly way, in compliance
with the regulations valid in the country where you
are.

Advertisement

Table of Contents
loading

Table of Contents