2. Remove internal climate sensor [6].
3. Remove the electronics cover [7]. Unlock
locking hook ( arrow) with screwdriver.
4. Fit supplied sealing strip centred in socket.
The sealing strip must be fitted to
AKE150 so that the units do not draw
in any unwanted air from outside.
7. Installation preparations │ UK

8. Mounting

For installation in square wall
sleeves, use ECA15-EMA16 spacing
frames  associated mounting
instructions.
8.1 Installation of external shutter
with outdoor climate sensor
1. Guide sensor connection cable [11]
through the wall breakthrough/wall sleeve
and pull it through to the other side of the
brickwork.
For the connection to the control
electronics, a maximum of 10 cm
is needed in the fan housing.
2. Guide the external shutter [12] into the
wall breakthrough/wall sleeve.
3. Fasten the sensor connection cable [11] in
the wall sleeve with adhesive tape.

8.2 Fan housing installation

1. Insert housing [1] into wall breakthrough/
wall sleeve (TOP must be at top).
2. Align housing horizontally and mark the
two dowel holes (arrows).
3. Remove housing [1], drill M6 dowel holes
with a Ø of 6 mm and insert dowels.