Maico EVR 31 Mounting And Operating Instructions

Maico EVR 31 Mounting And Operating Instructions

Window fans
Hide thumbs Also See for EVR 31:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Fensterventilatoren
Window Fans
Ventilateurs de fenêtre
EV 31
EVR 31
EVH 31
Montage- und Betriebsanleitung
Mounting and operating instructions
Instructions de montage et mode d'emploi
D
GB
F
w w w . m a i c o - v e n t i l a t o r e n . c o m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVR 31 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maico EVR 31

  • Page 1 Fensterventilatoren Window Fans Ventilateurs de fenêtre EV 31 EVR 31 EVH 31 Montage- und Betriebsanleitung Mounting and operating instructions Instructions de montage et mode d’emploi w w w . m a i c o - v e n t i l a t o r e n . c o m...
  • Page 3: Table Of Contents

    EV 31, EVR 31 und EVH 31 1. Warnsymbole Lebensgefahr! Lieferumfang Eine Nichtbeachtung kann zum Tod oder zu schweren ● Innengehäuse komplett GEFAHR Körperverletzungen führen. ● Flanschhülse Verletzungsgefahr! ● Außengitter Eine Nichtbeachtung kann zu ● Montageanleitung schweren Körperverletzungen ● Zubehör WARNUNG führen.
  • Page 4: Produktbeschreibung

    Büros, Geschäfts- und Gewerberäumen, Bemessungsspannung und -frequenz Gaststätten, Produktions- und Arbeits- ● Siehe Typenschild stätten, Arztpraxen etc. ● EVR 31: Zur Be- oder Entlüftung o. g. Räumlichkeiten. 4. Umgebungsbedingungen und ● Für den senkrechten Einbau in Fenster Grenzen für den Betrieb oder dünne Wände.
  • Page 5: Sicheres Und Korrektes Verhalten Für Den Betrieb

    ● in der Nähe von brennbaren Materialien,  Montageposition festlegen. Flüssigkeiten oder Gasen. Ausreichend Abstand (min. 50 mm) zum ● in explosionsfähiger Atmosphäre. Fensterrahmen oder zur Wand/Decke einhalten. Platz für eine ordnungsgemäße Leitungszuführung und Schwenkbereich Sicheres und korrektes Verhalten für des Fensters berücksichtigen.
  • Page 6: Montage

    7. Montage Hinweise Einbau in Fenster ● Auf Dichtigkeit an den Scheibenringen [7] Funktionsstörung und Ge- ACHTUNG und [10] achten. rätebeschädigung durch ● Bei Scheibendicke > 8 mm mitgelieferte streifendes Flügelrad [14] Schrauben [2] durch geeignete Schrauben bei fehlerhaftem Einbau! ersetzen (Schrauben bauseitig bereit- ...
  • Page 7: Elektrischer Anschluss

    Elektrischer Anschluss Montage Innengehäuse, Lebensgefahr durch siehe auch Abb. A, rechts unten Stromschlag! Kurzschluss und Geräte-  Netzsicherung ausschalten! GEFAHR beschädigung bei falscher Polung! Gerätebeschädigung bei VORSICHT  Beim Einstecken auf richtige Kurzschluss! Polung achten, siehe Auf-  Nicht benötigte Adern drucke A und B.
  • Page 8: Bedienung

     Gerät mit Schalter ausschalten. regelmäßigen Zeitabständen auf Innenverschluss schließt. Beschädigung überprüfen. Ventilator schaltet aus.  Bei Beschädigung die Anschlussleitung EVR 31 durch eine Fachkraft austauschen lassen.  Gerät mit Schalter (z. B. Wendeschalter STW..) einschalten. Innenverschluss öffnet automatisch. 10. Reinigung Ventilator läuft und be- oder entlüftet den...
  • Page 9: Störungsbehebung

    0185.0853.0007 dieser Anleitung, die Typenschild-Nr. „X“ des Gerätes und die jeweilige Positions-Nr. an. Pos. Seite 2, Bezeichnung Abb. A Innengehäuse komplett – EV 31, EVR 31 – EVH 31 Außengitter VM Verriegelung Motorgetriebe VM – EV 31, EVR 31 Tab. 2: Ersatzteile...
  • Page 10: Scope Of Delivery

    EV 31, EVR 31 and EVH 31 1. Warning symbols Danger to life Scope of delivery Non-observance can lead to death or serious bodily injuries. DANGER ● Internal housing, complete ● Connecting flange Danger of injury ● External grille Non-observance can lead to ●...
  • Page 11: Product Description

    ● EVH 31: 6.4 kg workplaces, doctors practices, etc. Rated voltage and frequency ● EVR 31: For ventilation or air extraction ● See rating plate. of the above-mentions premises. ● For vertical installation in windows or thin walls.
  • Page 12: Safe And Correct Practices During Operation

    ● close to flammable materials, liquids or  Decide on the installation position. gasses. Maintain sufficient distance (min. 50 mm) ● in explosive atmospheres. from the window frame or wall/ceiling. Allow enough space for a correct cable feed and the opening area of the window. Safe and correct practices during ...
  • Page 13: Installation

    7. Installation Notes Installation in windows ● Make sure there are no leaks at the Faulty operation and unit NOTICE window pane rings [7] and [10]. damage caused by a rubbing ● In the case of a window pane that is impeller [14] with incorrect >...
  • Page 14: Electrical Connection

    Electrical connection Internal housing installation Danger to life from electric see also Figure A, bottom right shock Danger of short-circuits and  Switch the mains fuse off. DANGER unit damage with wrong polarity CAUTION Unit damage in the case of ...
  • Page 15: Operation

    The internal shutter closes. The fan unit switches off. 10. Cleaning EVR 31  Switch the unit on using the switch, e.g. Danger to life. Unit is powered reversing switch STW… The internal shutter opens automatically.
  • Page 16: Fault Rectification

    “X” and the corresponding item number. Item, Page 2 Designation Figure A Internal housing, complete – EV 31, EVR 31 – EVH 31 External grille VM Catch VM motor gear – EV 31, EVR 31 Tab. 2: Spare parts...
  • Page 17: Éléments Fournis

    EV 31, EVR 31 et EVH 31 1. Symboles d'avertissement Danger de mort ! Éléments fournis Le non respect peut entraîner ● Boîtier intérieur complet des blessures corporelles ● Manchon d'assemblage DANGER graves, voire la mort. ● Grille extérieure Risque de blessure ! ●...
  • Page 18: Description Du Produit

    3 mm d’ouverture de ● Découpe de vitre: Diamètre 360 mm contact par pôle. ● EV 31, EVR 31: 7,6 kg ● Utiliser l'appareil exclusivement à la ● EVH 31: 6,4 kg tension et à la fréquence indiquées sur la plaque signalétique.
  • Page 19: Utilisation Conforme

    AVERTIS- verre ! Endommagement de la ● EVR 31: Pour l’évacuation d’air ou la SEMENT vitre dû aux tensions du ventilation des locaux ci-dessus. matériel ! ● Pour montage vertical en fenêtres ou en ...
  • Page 20: Montage Mural Et Sur Panneaux En Bois

     Faire effectuer la découpe de la vitre par 7. Montage un professionnel: diamètre 360 mm. Montage en fenêtre Dysfonctionnement et ATTENTION endommagement de l’appareil dus à un frottement de l’hélice [14] en cas de montage défectueux !  Installer le boîtier intérieur [1] ni gauchi ni coincé...
  • Page 21: Montage Mural Et Sur Panneaux En Bois

    Branchement électrique Remarques Risque d’électrocution ! ● Surveiller l’étanchéité des couronnes  Mettre le fusible secteur hors annulaires [7] et [10]. service ! ● En cas d’épaisseur de vitre > 8 mm, DANGER Endommagement de l’appareil remplacer les vis [2] par des vis en cas de court-circuit ! appropriées (vis à...
  • Page 22: Montage Du Boîtier Intérieur

     Mettre l’appareil à l’arrêt à l’aide de l’interrupteur. La fermeture intérieure se ferme. Le ventilateur se met à l’arrêt. EVR 31  Enclencher l’appareil à l’aide de l’interrupteur (inverseur STW par ex.). La fermeture intérieure s’ouvre automa- tiquement.
  • Page 23: Maintenance

    EVH 31 10. Nettoyage Endommagement de l’appa- ATTENTION Danger de mort, l'appareil est reil si la tirette est tirée par sous tension ! à-coups !  Mettre le fusible secteur hors  Ne pas tirer la tirette par à- DANGER service ! coups.
  • Page 24: Dépannage

    Pos. Page 2, Désignation Fig. A Boîtier intérieur complet – EV 31, EVR 31 – EVH 31 Grille extérieure VM Verrouillage Transmission moteur VM – EV 31, EVR 31 Tab. 2: Pièces de rechange...
  • Page 25: Schaltbilder

    Schaltbilder / Wiring diagram / Schémas de branchement...
  • Page 26 EVH 31...
  • Page 28 Maico Elektroapparate-Fabrik GmbH • Steinbeisstr. 20 • 78056 Villingen-Schwenningen • Deutschland • Technische Beratung +49 7720 694 447 • technik@maico.de...