Safe And Correct Practices During Operation; Installation Preparation; Installation In Windows; Installation In Walls And Wooden Panels - Maico EVR 31 Mounting And Operating Instructions

Window fans
Hide thumbs Also See for EVR 31:
Table of Contents

Advertisement

Available languages

Available languages

GB
● close to flammable materials, liquids or
gasses.
● in explosive atmospheres.
Safe and correct practices during
operation
● Danger of injury Do not insert any objects
in the unit.
● Danger from self-turning impeller Do not
get too close to the unit to avoid hair, clo-
thing or jewellery being drawn into the unit.
● The unit is not intended to be used by
people whose physical, sensory or mental
capabilities are not sufficient for them to
understand and put into practice the safety
information provided in these instructions.
This restriction also applies to children. The
unit may however be safely used by such
persons if they are supervised by someone
responsible for their safety or if they are
instructed in a suitable way.

6. Installation preparation

Installation in windows

Danger of cuts caused by
sharp glass edges and glass
breakage. Damage to the
WARNING
window pane from material
stress.
 If necessary, extract the
window pane and putty it back
in place without stress.
Functional impairment and
NOTICE
unit damage if installed on an
uneven substrate.
 Make sure there is a level
seating in the area of the
window pane rings [7] and [10].
Danger of short-circuits with
sloping installation position
through the build-up of
CAUTION
condensation inside the
housing.
 Only install the unit vertically,
with the cable feed from
above.
12
 Decide on the installation position.
Maintain sufficient distance (min. 50 mm)
from the window frame or wall/ceiling.
Allow enough space for a correct cable
feed and the opening area of the window.
 Get an expert to make the window cut-out
– diameter 360 mm.
 Lay the power cable.
Installation in walls and wooden
panels
 Make the same preparations for the
installation in walls and wooden panels as
described under Installation in windows.
Dismantling internal housing with
connecting flange, see Figure A,
bottom left.
 Loosen both catches [13] with a
screwdriver.
 Hold on to the internal housing, slightly
angle the connecting flange and disconnect
it from both locking hooks [3.1].
 Pull the connection terminal plug [12] off.
 Remove the testing cables from the
connection terminal socket [9]. These are
no longer required.