Download Print this page

Aqualisa Quartz QZ.A1.EV.05 Installation Instructions Manual page 7

Digital exposed with adjustable height head

Advertisement

3
Choose the position for your Digital processor as close to the shower control
as possible. The processor may be sited in the roof space above the proposed
shower site, in the airing cupboard or behind a screwed bath panel if more
convenient. If siting in the roof space, ensure that freezing cannot occur and
that no insulation material is placed under or over the processor. Please refer
to the system layout diagrams opposite.
!
The optimum position for the Digital processor
is in the roof space above the shower site to
take full advantage of the ease and speed of
installation.
For gravity fed and separately pumped systems,
the Digital processor MUST BE SITED NO
HIGHER than the base level of the cold water
storage cistern.
The distance between the processor and the
shower control must be within range of the
data cable supplied (10m).
The processor must be sited in a position so
that access can be gained for testing, service
and replacement purposes.
Check valves are supplied with the non-pumped
processor and should be fitted when used on
combination boiler systems.
4
Place the Digital processor on a solid
mounting surface, mark then drill and
prepare the fixings before securing the
processor to the mounting surface using the
screws supplied in screw pack no. 1.
5
Flush through both the 15mm copper hot and cold supply pipes.
!
The maximum hot water inlet temperature should be no more than 65˚C.
6
Attach the supply pipes to the Digital processor,
ensuring that the cold and hot feeds are fitted
into the appropriately marked inlets.
!
DO NOT SOLDER NEAR TO PLASTIC
COMPONENTS.
Quartz Digital exposed with adjustable height head installation instuctions
Hand tight only
Check valve
page 7