Step-by-step instructions
!
In addition to the guide below it is essential that the written instructions
overleaf are read and understood and that you have all the necessary
components (shown overleaf) before commencing installation. Failure to
install the product in accordance with these instructions may adversely affect
the warranty terms and conditions. Do not undertake any part of this
installation unless you are competent to do so. Prior to starting, ensure that
you are familiar with the necessary plumbing regulations required to install
the product correctly and safely.
!
The Quartz Digital is supplied with universal fittings.
1
The Quartz Digital processor must be fixed in one of the three orientations shown.
2
Isolation valves are supplied with the Digital
processor and must be fitted on both inlets and
the blended water outlet. For optimum
performance, all inlet pipe work should be in
15mm copper pipe. If plastic pipe is used, there
will be a restriction in flow rate and
performance. All pipe work should be supported.
!
For externally pumped gravity fed installations, 22mm pipe work should be
run as close to the processor as possible before reducing down to 15mm.
Quartz Digital exposed with adjustable height head installation instuctions
114mm
335mm
114mm