  • Page 2: Safety Information

    ™ a hot water supply temperature of over 65ºC. If See www.aqualisa.co.uk/guarantee for details. the maximum hot water temperature is likely to rise above 65ºC then a Thermostatic Blending Installation of the pumped Quartz Smart Valve must be used. Valve (for gravity stored systems) ™...
  • Page 3 It should be noted that these may result in poor shower performance. daytime pressures approaching 600kPa ((6 bar)(80psi)) can rise above the stated If at any stage during installation you have any maximum overnight. questions then please contact the Aqualisa...
  • Page 4: Declaration Of Conformity

    Water Supply Regulations prior to connection of the product. Declaration of conformity Aqualisa Products Limited declares that the Quartz Smart Valve and controller, in ™ conjunction with the diverter and remote...
  • Page 5 Concealed components (HP/Combi) Mains fed and separately pumped water Gravity stored water systems only systems only Exposed components (HP/Combi) Exposed components (Gravity Pumped) Mains fed and separately pumped water Gravity stored water systems only systems only Rise ™ Installation Guide 05...
  • Page 6 WALL MOUNTED COMPONENTS CEILING MOUNTED COMPONENTS Rise ™ Installation Guide 06...
  • Page 7 Wall mounted fixed head Ceiling mounted fixed head Rise concealed with Rise exposed with ™ ™ adjustable height head adjustable height head Rise ™ Installation Guide 07...
  • Page 8 Central boiler heating Central boiler heating boiler Supply Supply Supply Typical combination boiler installation Typical combination boiler installation (compatible with standard Quartz Smart Valve Rise ™ Installation Guide 08 Typical combination boiler installation (compatible with standard Quartz Smart Valve...
  • Page 9 Cold feed to cylinder Connect ‘A’ or ‘B’ Connect ‘A’ or ‘B’ Hot water NB: 1.5 bar MINIMUM cylinder universal pump rating Hot water NB: 1.5 bar MINIMUM cylinder universal pump rating Rise ™ Installation Guide 09...
  • Page 10: Installation

    • Ensure the distance between the Quartz Smart Valve and the aerial is as large as possible. ™ Installation videos are available on our website www.aqualisa.co.uk/installation-videos or alternatively, scan the QR codes on the reverse of this guide. Rise ™...
  • Page 11 For optimum performance on gravity fed systems 22mm pipe work should be run as close to the Quartz Rise ™ Installation Guide 11 smart valve as possible before reducing down to 15mm. All pipe...
  • Page 12 Care should be taken to ensure the mounting holes do not pierce the data cable conduit. If installing this Quartz Digital as a replacement shower, it may be necessary to purchase a Digital concealed retro-fit wall plate to first cover the existing Rise ™ Installation Guide 12...
  • Page 13 ™ If installing this Rise product as a replacement product, it may be necessary to purchase a concealed retro-fit wall plate to cover the existing hole in the tiling. The cavity in the wall should be plugged using a suitable material for the wall plate to be secured to.
  • Page 14 DO NOT use a compression fitting to connect the outlet pipe to the top of the Rise™ exposed product. This will affect the warranty. The black push fit elbow provided •...
  • Page 15 Prepare suitable fixings and slide the fixing bracket back over the rail onto the support pillar. Secure to the wall using the screws provided. Place the upper rail bracket support pillar into the desired location ensuring that both the hose restraint and the Aqualisa Pinch Grip ™ holder are below the rail wall bracket.
  • Page 16 We recommend protecting surface mounted cables in suitable approved conduit to avoid the risk of damage from vermin. • The power lead should also be clipped in place with ‘P’ clips or similar to avoid accidents. Rise ™ Installation Guide 16...
  • Page 17 Ensure the hose washer is in the correct position and screw the pivot hose connector into the hose. Re-insert the pivot hose connector into the handset and push the tab to lock into position, then place the handset into the Aqualisa ™ Pinch Grip holder.
  • Page 18 Site conditions can affect temperature settings, installer to adjust as required. • ™ The Rise product has a number of additional functions available. Please note these features are disabled as a factory default. To activate and programme these features please refer to the separate user guide for commissioning and user instructions on how to operate the shower.
  • Page 19 Trim the projecting pipe to a length of 15-22mm, measured from the face of the gripper ring, using a rotary type cutter. If a hacksaw is used, the pipe end must be carefully de-burred and chamfered. Rise ™ Installation Guide 19...
  • Page 20 Place the ‘O’ ring on the recess of the spigot section on the mounting plate, offer the wall outlet onto the mounting plate in the 5 o’clock position and rotate clockwise until a stop is reached. Refit the locking screw taking care not to overtighten. Rise ™ Installation Guide 20...
  • Page 21 Pass the rail through the Aqualisa Pinch Grip holder while keeping ™ the slider levers depressed. Carefully slide the gel hook onto the rail under the Aqualisa Pinch Grip holder . ™ Current Water Supply Regulations state that the handset should not be allowed to pass a point 25mm above the spill over level of the bath or shower tray.
  • Page 22 Pass the hose through the gel hook. To attach the handset to the hose, remove the anti-swivel connector from the handset by pressing the tab in on the retaining clip and pulling the anti-swivel connector clear from the head. Rise ™ Installation Guide 22...
  • Page 23 Push the silver accent ring and Aqualisa badge into the centre of the shower head to cover the screw, and remove the protective film.
  • Page 24 Lubricate the ‘O’ ring using a suitable silicone based lubricant. The ‘O’ ring must be positioned on the 15mm pipe flush to the fixing bush, not onto the fixing bush shaft. • Rise ™ Installation Guide 24...
  • Page 25 Ensuring the rubber washer is in the correct position, attach the shower head to the fixed arm and carefully secure using a suitable spanner, or a tool with smooth jaws, sufficiently to lock the head into position. Rise ™ Installation Guide 25...
  • Page 26 The minimum height required behind the ceiling is 50mm and the space must allow for an 80mm wide, 50mm deep noggin to be used to support the assembly. • Rise ™ Installation Guide 26...
  • Page 27 Run the shower for a few seconds to clear any debris and to check for any leaks. • Lubricate the ‘O’ ring if necessary and carefully slide the cover plate back over the fixed head arm and into position against the ceiling. Rise ™ Installation Guide 27...
  • Page 28 Ensuring the rubber washer is in the correct position, attach the shower head to the fixed arm and carefully secure using a suitable spanner, or a tool with smooth jaws, sufficiently to lock the head into position. Rise ™ Installation Guide 28...
  • Page 29 To avoid residual water dripping from the shower head after use, we advise to tilt the head to allow residual water to drain out. • The above recommendation applies to both adjustable and fixed shower heads. Rise ™ Installation Guide 29...
  • Page 30: Cleaning And Maintenance

    1. To select one of three spray patterns, rotate the shower spray cassette clockwise or anti-clockwise. 2. To select the preferred height for the shower head, depress the levers fully to enable the Aqualisa Pinch Grip holder to ™ be moved up or down the rail.