Firegear PRO Series Installation And Operating Instructions Manual

Firegear PRO Series Installation And Operating Instructions Manual

Fire pit burners with all weather electronic ignition system

Advertisement

Quick Links

"PRO SERIES"
Model
N= Natural / P= Propane
LOF-3010PS246AWS-N/P
LOF-3610PS306AWS-N/P
LOF-4810PS406AWS-N/P
LOF-6010PS506AWS-N/P
LOF-7210PS606AWS-N/P
LOF-9610PS806AWS-N/P
All Weather Electronic Ignition System (AWS)
Installation and Operating Instructions
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS
DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE
This system requires a minimum 18-square inches (per side) of cross ventilation.
Failure to provide proper ventilation will void the warranty.
Warning: For Outdoor Use Only
H-Burner
30"x 10" Linear Flat Pan & 24" x 6" Pro H-Burner
36"x 10" Linear Flat Pan & 30" x 6" Pro H-Burner
48"x 10" Linear Flat Pan & 48" x 6" Pro H-Burner
60"x 10" Linear Flat Pan & 60" x 6" Pro H-Burner
72"x 10" Linear Flat Pan & 72" x 6" Pro H-Burner
96"x 10" Linear Flat Pan & 80" x 6" Pro H-Burner
Pro Series Fire Pit Burners with
INSTALLATION PRECAUTION:
DO NOT DISCARD. THIS MANUAL
HAS IMPORTANT OPERATING AND
MAINTENANCE INSTRUCTIONS.
LEAVE WITH THE HOMEOWNER.
MODEL:
SERIAL #:
Description
PN#90200

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Firegear PRO Series

  • Page 1 72”x 10” Linear Flat Pan & 72” x 6” Pro H-Burner LOF-9610PS806AWS-N/P 96”x 10” Linear Flat Pan & 80” x 6” Pro H-Burner Pro Series Fire Pit Burners with All Weather Electronic Ignition System (AWS) Installation and Operating Instructions IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS...
  • Page 2 State of California to cause cancer, birth defects and other reproductive harm and Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive harm. (For more information go to: www.p65Warnings.ca.gov.) Pro Series LOF Fire Pits with AWS System REV. B Page 2...
  • Page 3: Table Of Contents

    Optional Accessories Warranty Congratulations! You have just purchased a Firegear Outdoors “Pro Series” H-Burner. These are Brass Burners that come in six sizes, 24”, 30”, 40” 50” 60” and 80”models. Each model is 6¾” wide and incorporates individual injectors that eliminates the need for a main burner orifice. The 24” model incorporates 20 injectors where up to the 80”...
  • Page 4: Specifications

    BTU’s. As a Fig. 2 Clearance to Combustibles for result your BTU’s may vary slightly from Table 2 specifications. models. (Not to be used in an enclosed space) Pro Series LOF Fire Pits with AWS System REV. B Page 4...
  • Page 5: Preparing A Non Combustible Structure

    290,000 Btu’s. The system this manual for a Firegear burner. NOTE: Depending on features a built-in safety shut-off in case of flame loss and venting locations, do not place fire pit directly on grass, auto-relight.
  • Page 6: Gas Pipe Sizing Chart

    This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel Gas Code - current edition) for more details. Table 4 Gas Pipe Sizing Chart Pro Series LOF Fire Pits with AWS System REV. B Page 6...
  • Page 7: Carton Contents - Single Fire Feature

    Fig. 5. Note: Check for any gas leaks after gas is connected and turned ON. Hardware Bag (included with fire pit) Fig. 5 Hardware bag contents. Pro Series LOF Fire Pits with AWS System REV. B Page 7...
  • Page 8: Pre-Installation Check List For Single Installation

    - installed 10-feet or greater from a pool or spa. This power supply has a 3-foot power cord to Injectors/Jets - Fire features using a Firegear Pro Series plug into 120VAC outlet and a 3-foot leads to connect to the brass burner incorporates individual injectors/jets on each gas valve on the 30VDC side.
  • Page 9: Power Supply Location For Single Installation

    Fig. 7 Example of a single fire feature install with power supply and switch contained within the enclosure, when applicable. Note: Must be 10-feet or more from a pool/spa for this installation. See additional illustration on page 10, Fig. 8. Pro Series LOF Fire Pits with AWS System REV. B Page 9...
  • Page 10: Burner Pan & Enclosure Preparation

    Fig. 9 Shows any fire feature installed within 5 feet of a pool or spa requires FG-PS-30V320 power supply (purchased DO NOT USE THE GOE-30VDC. FG-PS-30V320 power supply can be installed up to a maximum of separately). 500-feet away from fire pit. Pro Series LOF Fire Pits with AWS System REV. B Page 10...
  • Page 11: Media Installation

    Firegear Outdoors 17322 Gothard St. Huntington Beach, CA 92647 Web Site: www.firegearoutdoors.com Manual changes often occur, ensure to check the Firegear Outdoor website for any recent updates and warranty information. Pro Series LOF Fire Pits with AWS System REV. B...
  • Page 12: Operating- Lighting Instructions

    1. Turn the fire feature OFF by pressing the OFF button of the switch or timer if applicable. 2. If you are no longer burning the fire pit until another time, we recommend turning the key valve to OFF position. Pro Series LOF Fire Pits with AWS System REV. B...
  • Page 13: Replacements Parts

    AWS REPLACEMENT PARTS GOE-30VDC Items are not to scale 15-20 Pro Series LOF Fire Pits with AWS System REV. B Page 13...
  • Page 14: Replacement Parts List & Valve Reference

    78045 96”x 10” LH-Burner Pan Only (used with 93” x 6” burner) 78062 Valve Box Reference 2-pin Igniter Connector 2-pin Thermopile Connector Flared Pilot Connection Compression Pilot Connection Pro Series LOF Fire Pits with AWS System REV. B Page 14...
  • Page 15: Troubleshooting

    Use a multi-meter to check resistance. Resistance should be 2.0 - 4.5 ohms. If no resistance or resistance greater than 8 ohms indicates a defective igniter. Pro Series LOF Fire Pits with AWS System REV. B...
  • Page 16 Thermopile is not defective the only thing left is a Defective Controller inside the valve box. If you have a Defective Controller the only way to fix it is to replace it. Pro Series LOF Fire Pits with AWS System REV. B...
  • Page 17 Often this will result in a small flame that continues to burn on the Main Burner after the feature has been turned OFF. Pro Series LOF Fire Pits with AWS System REV. B Page 17...
  • Page 18: Optional Accessories

    Match Throw (MT) Burning Spur fire key valve pit to use with kit listed above (sold separately). Note: See the Firegear Outdoors catalogue for other accessories available not listed above. Pro Series LOF Fire Pits with AWS System REV. B Page 18...
  • Page 19: Warranty

    FIREGEAR LIMITED WARRANTY - 2021 Firegear Outdoors hereby warrants to the end user that products will be free from material and workmanship defects that prevent safe and correct operation of the product. The warranty commences from date of sale to the end user for the following period: CONSUMER RESIDENTIAL APPLICATIONS –...
  • Page 20 LIFETIME WARRANTY - CONSTRUCTION AND MANUFACTURER DEFECTS • LIFETIME WARRANTY - STAINLESS STEEL COMPONENTS (LIDS, STAINLESS STEEL COVERS) • ONE (1) YEAR WARRANTY – ESTOP1-OH, ESTOP2-5H WINDSHIELDS, HOSES AND REGULATORS Pro Series LOF Fire Pits with AWS System REV. B Page 20...
  • Page 21 Product to be returned should; be packed so as not to incur damages during transportation. Firegear is not responsible for damages on returned items. RMA is valid for thirty (30) days from the date issued. The RMA must be clearly marked on the outside of the package.
  • Page 22 Firegear Outdoors 17322 Gothard St Huntington Beach, CA 92647 Web Site: www.firegearoutdoors.com Manual changes often occur, ensure to check the Firegear Outdoor website for any recent updates and warranty information. Pro Series LOF Fire Pits with AWS System REV. B...
  • Page 23 Be prepared to send photos to us when on the phone. 10. Found missing or damaged parts? Let us know ASAP or send photos. Fire Pits Pro Series LOF Fire Pits with AWS System FPSS 3-30-16 REV. B Page 23...

This manual is also suitable for:

Lof-3010ps246aws-nLof-3610ps306aws-nLof-4810ps406aws-nLof-6010ps506aws-nLof-7210ps606aws-nLof-9610ps806aws-n ... Show all

Table of Contents