Function Selection Mode

■Function selection mode
In measurement mode, press the
the function to be changed [F□□]. Press and hold the
selection mode to return to measurement mode.
: Some products do not have all the functions. If no function is available or selected due to configuration of other functions, [- - -] is
displayed on the sub display (right).

■Default setting

The default setting is as follows.
If no problem is caused by this setting, keep these settings.
To change a setting, enter function selection mode.
●[F 0] Units selection function
Units specification
"Nil" or M
P
●[F 1] Setting of OUT1
Item
Either hysteresis mode, window comparator mode, error output or
Output mode
output off can be selected.
Reversed output
Selects which type of switch output is used, normal or reversed.
Pressure setting
Sets the ON and OFF point of the switch output.
Appropriate setting of the hysteresis will prevent the switch output
Hysteresis
from chattering.
Delay time
Delay time of the switch output can be selected.
Display color
Selects the output according to the display color.
button between 3 and 5 seconds, to display [F 0]. Select to display
Page
30
Pressure range
Default setting
ISE20A
MPa
ZSE20A(F)
ISE20A
ZSE20A(F)
Page
31
Explanation
-28-
button for 2 seconds or longer in function
kPa
psi
Default setting
Hysteresis mode
Normal output
ISE20A
: 0.500 MPa
ZSE20A : -50.5 kPa
ZSE20AF : 50.0 kPa
ISE20A
: 0.050 MPa
ZSE20A : 5.1 kPa
ZSE20AF : 5.0 kPa
1.5 ms or less
OUT1 ON : Green
OUT1 OFF: Red
No.PS※※-OMU0003-C