Problem
Problem
No.
Copy error [Er13]
is displayed on
18
the slave side
pressure switch.
The operation is
19
unstable.
(chattering)
Problem possible
causes
(1) Check the wiring connection at
the FUNC terminal.
Incorrect wiring
Check the power supply wiring.
(2) Check the lead wire lengths.
The model number of the master
Improper model
Pressure switch and the slave
selected
Pressure switch are different from
each other.
Too many
pressure
Check the number of connected
switches
slave Pressure switches.
connected
Product failure
Effect of line
pressure
fluctuation
(1) Check the set pressure values
because
(hysteresis)
hysteresis is too
(2) Check the delay time.
narrow or delay
time of the switch
is too short
(1) Check the power supply wiring.
Incorrect wiring
(2) Check if there is bending stress
or broken lead
applied to any parts of the lead
wire
wire.
Product failure
-73-
Investigation method
Countermeasures
(1) Correct the wiring.
(2) The maximum
transmitting distance of
the copy function is 4 m.
Shorten the lead wire to
4 m or less.
Check the model numbers.
Copying is available when
the pressure range, output
specification and units
specification are identical.
The number of connected
products for which copying is
possible is up to 10 pcs.
Reduce the number to 10
pcs. or less.
Replace the product.
(1) Check the pressure
setting.
(2) Reset the function
settings.
(1) Correct the wiring
(2) Correct the wiring
conditions (reduce the
tensile force and
increase the bending
radius).
Replace the product.