MFR-DB
Boot Confirmation
This gives a clear visual confirmation at power on whether or not the MFR-DB Camera has
initialised successfully the following hardware is tested during boot sequence:
•
Optical Camera Module Comms
•
Thermal Camera Module Comms
•
Tilt Axle Encoder
•
Pan Axle Encoder
•
Accelerometer
The feature can be enabled/disabled in the
Successful Boot
The camera will emulate a head nod on a successful initialisation, the actual movement sequence
is defined as follows:
•
Tilt to 0° (Straight Ahead)
•
Tilt Down 20°
•
Tilt Up 20°
•
Return to Start-Up Angle
Boot Fail
If during the boot sequence any hardware faults are detected the camera will emulate a head
shake, the actual movement sequence is defined as follows:
•
Pan to 0°
•
Pan Left 30°
•
Pan Right 60°
•
Pan Left 60°
•
Pan Right 30°
•
Return to Start-Up Angle
visualengineering.co.uk
Motor Options
boot menu�