Configuring the Camera

The MFR-DB can be configured for a specific user profile, to include; communication settings, motor
control, and camera options. Once configured the camera will retain the settings.
The camera is configured using a menu structure on its control interface which is only accessible
at power on� To access the control menu it is necessary to connect the camera to a serial comms
software application, such as TeraTerm set to 9600 baud 8n1�

Boot Menu

Connect the power comms cable to a USB
port on a PC�
Open the PC serial comms application
Power on the camera, a > character will
appear and shortly after a ! character�
As soon as the ! appears type v e in quick
succession�
The Main Menu shown on the right will then
be displayed�
Select the required option�
The function options are described in the
following tables�

Comm Port Options

Sub Menu
Mode
Baud Rate
Protocol
Unit Address
visualengineering.co.uk
Description
The serial comms standard
The serial comms baud rate
The PTZ control protocol
The camera's unit address, this allows
several cameras to be connected on the
same comms bus
>!
MFR-DB
Software: v2.0.0
MAIN MENU:
1 = Comm Port
2 = Motor
3 = Camera
t = Start Diagnostic Test
x = Exit
Comm Port Options
Options
RS485, No Parity , RS232, No Parity,
RS485, Odd Parity, RS232, Odd Parity
RS485, Even Parity, RS232, Even Parity
1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200
Auto Detect, Visca,
PelcoD, PelcoP
1, 2, 3, 4, 5, 6, 7
December 2021
Page 6