MFR-DB
Flir Pass Through
Through the camera's serial comms path the thermal camera module can be controlled using
standard FLIR protocol, which is wrapped using the following custom VISCA command/response�
The payload of the command/response is the standard FLIR command�
Send Command
8[x]
0x01
[x]
= The Unit Address, which can be set in the
[a]
= Payload Length
[b]
= Standard Flir Command Payload, variable length
Response Acknowledge
[y]0
Response Complete
[y]0
0x51
[y]
= The Unit Address+8�
[a]
= Payload Length
[b]
= Standard Flir Command Payload, variable length
visualengineering.co.uk
0x04
0x24
0x24
0x9F
0x9F
0x01
Comm Port Options
0x41
0x01
[a]
[b]
in the boot menu�
0xFF
[a]
[b]
December 2021
0xFF
0xFF
Page 12
Need help?
Do you have a question about the MFR-DB and is the answer not in the manual?
Questions and answers