Through the camera's serial comms path the thermal camera module can be controlled using
standard FLIR protocol, which is wrapped using the following custom VISCA command/response�
The payload of the command/response is the standard FLIR command�
Send Command
8[x]
0x01
[x]
= The Unit Address, which can be set in the
[a]
= Payload Length
[b]
= Standard Flir Command Payload, variable length
Response Acknowledge
[y]0
Response Complete
[y]0
0x51
[y]
= The Unit Address+8�
[a]
= Payload Length
[b]
= Standard Flir Command Payload, variable length