Setup Proflame; Initialize The Control System; Reset The System For Manual Operation; Automatic Safety Restart - kozy heat CHASKA 29-LOG Installation And Operation Manual

Direct vent gas fireplace insert
Hide thumbs Also See for CHASKA 29-LOG:
Table of Contents

Advertisement

11.1 Setup Proflame 2 IFC Module
1.
Set the main ON/OFF rocker switch in the OFF position.
2.
Install (4) AA batteries (included in the components packet)
into backup battery holder on the control module.
3.
Install (3) AAA batteries (included in the components packet)
in the remote control battery bay, located at the base of the
remote.
4.
Connect the IFC Module to an AC power supply.

11.2 Initialize the Control System

IMPORTANT: Remove all packaging and combustible material
from the firebox before initializing the control system.
NOTE: Performing the next steps will initiate pilot start-up in
manual mode, where the pilot igniter will spark repeatedly. The
pilot will ignite if gas is supplied to the fireplace.
1.
Locate the red SW1 button the IFC module.
2.
Press the button. The IFC module will BEEP (3) times and
illuminate an amber LED. This indicates the receiver is ready
to synchronize with the transmitter.
3.
Within (5) seconds, push the ON/OFF button on the
remote control. The receiver will BEEP (4) times to indicate
the transmitter's command is accepted, and is set to the
transmitter's particular code. The pilot will automatically ignite.
4.
Press the remote control ON/OFF button again. The pilot
will extinguish, confirming the remote control command. The
control system is now initialized.
5.
Set the main ON/OFF rocker switch to ON position for remote
control operation of the main burner and fireplace features.
SW1
BUTTON
LEDs
Figure 11.1, IFC Module
11.3 Reset the System for
Manual Operation
1.
Set the ON/OFF rocker switch to OFF position.
2.
Press the red SWI button on the IFC module until it emits (3)
beeps and an amber LED is illuminated.
3.
Within (5) seconds, press the red SWI button again. This will
close synchronization with the remote control. The pilot will
automatically light.
Turn the main burner ON by setting the ON/OFF switch in ON
position. The main burner will only operate on HI.
26 OPERATING INSTRUCTIONS
Turn the main burner OFF by setting the ON/OFF switch in the
OFF position. The pilot will remain lit even if burner is turned
off, provided CPI mode is turned on.

11.4 Automatic Safety Restart

This system will execute an automatic turn OFF command
within (24) hours of a continued pilot flame ignition. This allows
the system to verify correct safety functions.
After the turn OFF sequence is completed, the IFC module will
re-execute the latest command.

11.5 Backup Battery Operation

This appliance will operate on the backup battery pack when
electric power is interrupted, or in a power outage. The lifespan of
the backup batteries depend on various factors, such as the quality
of the batteries, number of ignitions, et cetera.
When the backup battery pack is low, the IFC module will emit
a double-beep while receiving an ON/OFF command.
No commands will be accepted after this alert until the back
up batteries are replaced.
Once replaced, the IFC module will emit a 'beep' as soon as
it is powered.