Parameter range
<freq>
10e3 to 50e6
<ampl>
10e-3 to 10
<offs>
-4.5 to +4.5
<phase>
0 to 360
APPLy:SINusoid?
Response
The LW120 will return <freq>, <ampl>,<offs>,<phase>. Default values are
APPLy:TRIangle{<freq>,<ampl>,<offs>,<phase>}
Purpose
This command is a high-level command that programs the LW120 to output triangular waveform along with
its associated parameters
<freq> sets the output frequency in units of hertz
<ampl> sets the output amplitude in units of volts
<offs> sets the output offset in units of volts
<phase> sets the output start phase in units of degrees
Parameter type
Numeric
Parameter range
<freq>
10e3 to 50e6
<ampl>
10e-3 to 10
<offs>
-4.5 to +4.5
<phase>
0 to 360
APPLy:TRIangle?
Response
The LW120 will return <freq>, <ampl>,<offs>,<phase>. Default values are
APPLy:SQUare{<freq>,<ampl>,<offs>,<duty_cycle>}
Purpose
This command is a high-level command that programs the LW120 to output square waveform along with its
associated parameters
<freq> sets the output frequency in units of hertz
<ampl> sets the output amplitude in units of volts
<offs> sets the output offset in units of volts
<duty_cycle> sets the squarewave duty cycle in units of %
Parameter type
Numeric
Parameter range
<freq>
10e3 to 50e6
<ampl>
10e-3 to 10
<offs>
-4.5 to +4.5
<duty_cycle> 0 to 360
Remote Programming Reference 4-14
User Manual LW120
1e6,5,0,0
1e6,5,0,0