FM:FUNCtion:SHAPe(SINusoid|TRIangle|SQUare|RAMP}
Purpose
This command will select one of the waveform shapes as the active modulating waveform.
SINusoid will select sine shape as modulating waveform
TRIangle will select triangular shape as modulating waveform
SQUare will select square shape as modulating waveform
RAMP will select ramp shape as modulating waveform
Parameter type
Discrete
FM:FUNCtion:SHAPe?
Response and default
The LW120 will return SIN, TRI, SQU, or RAMP depending on its present setting. Default is SIN.
FM:FREQuency<FM_freq>
Purpose
This command will set the modulating wave frequency. This parameter affects the LW120 when set to
operate in FM:FUNC:MODE FIX
<FM_freq> will set the frequency of the modulating waveform
Parameter type
Numeric
Parameter range
<FM_freq>
1e-3 to 100e6 in units of hertz
FM:FREQuency?
Response and default
The LW120 will return the present modulating waveform frequency value. The returned value will be in
standard scientific format (for example: 100mHz would be returned as 100E-3 – positive numbers are
unsigned). Default value is 1e3.
FM:FREQuency:RASTer(?)<FM_sclk>
Purpose
This command will set the modulating wave sample clock frequency. This parameter affects the LW120
when set to operate in FM:FUNC:MODE USER
<FM_sclk> will set the sample clock frequency of the modulating waveform
Parameter type
Numeric
Parameter range
<FM_sclk>
1e-3 to 10e6 in units of samples per second
Remote Programming Reference 4-21