Thermoplan BLACK&WHITE 3 FOX2 Technical Manual page 9

Advertisement

User messages
Text message
o.
Please
rinse unit
p.
Refill milk
q.
Powder Error
r.
Cleaning break
insert tablet
s.
Cleaning key missing
Please insert
t.
Cleaning
Press cleaning key
u.
RF temp
too low
© 2010 Thermoplan AG, Subject to change
Technical Manual
Reason / solution
• Cold start rinse has to be performed to ensure that the system is filled
with water
Press rinse key
• Flowmeter not working correctly
Check flowmeter
• Change hydraulic module
• Milk container is almost empty, dispensing of products still possible
Refill milk container with milk
• Too much coffee is ground, exceeding the fill capacity in brew chamber
Check the powder quantity and adjust the grinder finer
• Defective 24V piston motor
• Drive screw or brew chamber contaminated
• Change mechanic module
• Cleaning was interrupted (power outage during cleaning)
Start daily cleaning again
• Cleaning key is not correctly mounted
Insert cleaning key and turn it 90° clockwise
• Defective solenoid switch of cleaning key
• Cleaning has to be started again
• Info message, refrigerator temp is lower than 4 °C
if on short notice, only as info
if permanent, check refrigerator for freezing
Check the refrigerators temperature sensor